background image

1 2 3 4 5

6 7 8 9

7

General Module Information

9-pin male SUB-D connector

Interface pin assignment:
1  Module output (±5 V) 

2  RS-485 (A) 

3  RS-485 (B) 

4 GND 

5  +9 V power supply 

6  +12 V power / sensor supply 

7  Module input (from D/A 

  converter of the A/D board)

1)

 

8 reserved 

9  -9 V power supply

1)

Triggerout at DAQP-FREQ-A

Calibration information

All DEWETRON modules are calibrated at 25 °C after a warmup time of 30 minutes and meet their 

specifications when leaving the factory.

 

The time interval for recalibration depends on environmental conditions. Typically, the calibration should be 

checked once a year.

Calibration certificates are available from DEWETRON as an option. DEWETRON offers two types:

 ISO traceable DEWETRON certificate

 Calibration certificate according to ÖKD (equivalent to DKD)

This manual contains no calibration information. For self calibration, there is a separate calibration kit for the 

DAQ series modules available. The CAL-KIT contains the required cables, software and instructions.

General module specifications

Module dimensions: 

20 x 65 x 105 mm 

(0.79 x 2.56 x 4.13 in.) 

(W x H x D without front cover and connectors)

Frontcover: 

20 x 87 x 2 mm 

(0.79 x 3.43 x 0.08 in.) 

(W x H x D without connector)

Environmental: 

Temp. range storage: 

-30 °C to +85 °C

(-22 °F to 185 °F) 

Temp. range operating:  -5 °C to +60 °C

(23 °F to 140 °F)

Relative humidity 

(MIL202): 

0 to 95 % at 60 °C, non-condensing (unless otherwise noticed)

RFI susceptibility: 

±0.5 % span error at 400 MHz, 5 W, 3 m

All specifications within this manual are valid at 25 °C!

All modules are produced according ISO9001 and ISO14001.

Module connectors

Frontpanel connector: 

Accessable to the user. The connector type and pin assignment varies 

from module to module. Detailed pin assignment of each module is 

shown in the appropriate module description.

Rear connector: 

9-pin male SUB-D, interface to the DEWE-System, not accessable to the user.

HSI/DAQx and PAD module 

rear view

450134 • DAQP/H

SI

/PAD Modules • Technical Reference Manual • Prin

t

ing version 2.3.4 • November 18, 2020

Содержание DAQP-ACC-A

Страница 1: ...l supply you with accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw u...

Страница 2: ...protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and regis...

Страница 3: ...se of the information in this document Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and se...

Страница 4: ...wing general safety precautions must be observed during all phases of operation service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this...

Страница 5: ...ained Keep away from live circuits Operating personnel must not remove equipment covers or shields Procedures involving the removal of covers or shields are for use by service trained personnel only U...

Страница 6: ...com The telephone hotline is available Monday to Friday between 08 00 and 12 00 CET GMT 1 00 and Monday to Thursday between 13 00 and 17 00 CET For the Americas please contact DEWETRON Inc 2850 South...

Страница 7: ...AQ series modules available The CAL KIT contains the required cables software and instructions General module specifications Module dimensions 20 x 65 x 105 mm 0 79 x 2 56 x 4 13 in W x H x D without...

Страница 8: ...e FILTER button again Approx 3 seconds after the last key activity the information will be stored the LED stops flashing and shows the input range again CAUTION Power loss during this time leaves the...

Страница 9: ...lected highpass filter to 300 kHz 2 to 5 dB fg Filters highpass 0 5 Hz filter 5 Hz filter 0 5 Hz and 5 Hz software selection 0 32 s time constant 0 032 s time constant Filters lowpass 1 kHz 10 kHz 100...

Страница 10: ...he GAIN button several times until the LED displays the desired input range Filter button Push the FILTER button once the LEDs will flash for approx 3 seconds and display the current filter setting Pu...

Страница 11: ...ber States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93 68 EEC 89 336 EEC Directive on the approximation of the laws of the Member States...

Страница 12: ...C2 Notes...

Отзывы: