3
English
CONTENTS
WARNINGS
2
HEATER SPECIFICATIONS
3
OPERATING & SAFETY PRECAUTIONS
4
LIGHTING/OPERATING INSTRUCTIONS
5
MAINTENANCE
5
EXPLODED VIEW AND PARTS LIST
8
WIRING DIAGRAM
11
Model
DXH80KTHC
DXH140KTHC
DXH210KTHCX
Burn Rate
80,000 BTU/hr (23.4 kW)
140,000 BTU/hr (41.2 kW)
210,000 BTU/hr (61.5 kW)
Fuel Rate
.59 gal/hr (3.9 L/hr)
1.0 gal/hr (3.9 L/hr)
1.6 gal/hr (6.0 L/hr)
Electrical Input
115 V, 60 HZ, 1 Ø, 4.0 A
115 V, 60 HZ, 1 Ø, 5.5 A
115 V, 60 HZ, 1 Ø, 5.5 A
Line Protection
10 A
10 A
10 A
Min. operating voltage
110 V
110 V
110 V
Pressure Setting
4.2 psig (29 kPa)
6.8 psig (47 kPa)
8.4 psig (58 kPa)
Max. Outlet Temp.
1300 °F (704 °C)
1300 °F (704 °C)
1300 °F (704 °C)
Fuel Tank Capacity
6 gallons (22.7 L)
10 gallons (37.9 L)
15 gallons (56.8 L)
Ignition
Direct Spark, Continuous
Direct Spark, Continuous
Direct Spark, Continuous
Spark Generator
Igniter, 12 kV, 0.36 A
Igniter, 12 kV, 0.36 A
Igniter, 12 kV, 0.36 A
Primary Safety Control
Solid State Control
Solid State Control
Solid State Control
Certification
Heater Specifications
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- Service must be performed by a qualified service agency.
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
Minimum Clearances:
Outlet: 8 feet (250 cm) / Sides, Top, Rear: 3 feet (91.4 cm)
Содержание DXH140KTHC
Страница 9: ...9 English DXH140KTHC DXH210KTHCX ...
Страница 21: ...9 Français DXH140KTHC DXH210KTHCX ...
Страница 33: ...9 Español DXH140KTHC DXH210KTHCX ...