Shut-down (Fig. 1)
1. Move Auto/Off switch to the OFF position.
NOTE:
If finished
using compressor, follow Steps 2 - 6.
2. Pull the regulator knob out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push
knob in to lock in place.
3. Remove hose and accessory.
WARNING:
Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see
Draining Air Tank
under
Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING:
Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
MAINTENANCE
Maintenance Chart
Procedure
Dail
y
W
eekl
y
Monthl
y
1 y
ear
or 1
00
Hour
s
See tank
w
ar
ning
label
Check safety valve
X
Inspect air filter
X+
Drain air tank
X
OPEN
CLOSE
FIG. 3
OFF
AUTO