background image

second.

Notice

: Including a node ID allocated by Z-Wave

TM

  Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

   

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the inclusion mode.

3. After inclusion successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the exclusion mode.

Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 

that the primary controller is lost or 

otherwise inoperable.

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will light ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 

successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

Association 1. Have Z-Wave

TM

 Controller entered association 

mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the association mode.

Note: The device support 2 groups. The group 1 is for 

receiving the report message, like triggered event, 

temperature, illumination etc. The group 2 is for light 

control, the device will send the “Basic Set” command 

to this group. And each group support 8 nodes 

maximum.

Failed or success in including/excluding the node ID can be 

viewed from Z-Wave

TM

 Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network 

Notice 2:

 When the device into NWI mode, the sensor functionality 

will useless. The NWI mode will timeout after 30 seconds. You can 

press the tamper key 3 times to abort the NWI mode.

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

The wake-up interval minimum setting is 30 minutes, and maximum

setting is 120 hours. And the interval step is 30 minutes.

If the user want to wake-up the device immediately, please remove the

front cover, and press the tamper key once. The device will wake-up 10

seconds.

Z-Wave

TM

 Message Report

When   the   Motion   Detector   triggered   or   the   Door/Window   Contact

triggered, the device will report the trigger event and also report the

battery status, temperature and illumination level.

2

Содержание MT 02648

Страница 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Страница 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Страница 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Страница 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Страница 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Страница 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Страница 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Страница 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Страница 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Отзывы: