In default the device  will  using  Notification  Report  to  represent the

trigger event, it can be changed to Sensor Binary Report by setting the

configuration NO. 7 Bit4 to 1.

* Motion Report:

When the Motion Detector detected, the device will unsolicited to send

the report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Home Security (0x07)

Event: Motion Detection, Unknown Location (0x08)
Sensor Binary Report (V2)
Sensor Type: Motion (0x0C)

Sensor Value: 0xFF

* Door/Window Report:

When the door/window state changed, the device will unsolicited to

send the report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Access Control (0x06)

Event: Door/Window is open (0x16)

          Door/Window is closed (0x17)
Sensor Binary Report (V2)
Sensor Type: Door/Window (0x0A)

Sensor Value: 0x00 is closed, 0xFF is opened.

* Tamper Report:

Both the 2 tamper keys are pressed over 5 seconds. The device will

into the alarm state. In that state, if any one of the tamper keys be

released, the device will unsolicited to send the report to the nodes in

the group 1.

Notification Report (V4)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)

Sensor Value: 0xFF

* Temperature Report:

When the Motion Detector detected or the Door/Window Contact state

changed,   the   device   will   unsolicited   to   send   the  “Sensor   Multilevel

Report” to the nodes in the group 1.

Sensor Type: Temperature (0x01)

Note: To disable this functionality by setting the configuration N0.5 bit5

to 1.

*** Temperature differential report ***

This function default is enabled, to disable this function by setting the

configuration NO.21 to 0.

In the default, when the temperature is changed to plus or minus one

degree   Fahrenheit   (0.56   degree   Celsius),   the   device   will   report

temperature information to the nodes in the group 1. 

The device will measure the temperature in every one minute. And if

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the

device will always report in each measurement. 

Caution 1

:

 Enable this functionality, it will cause the PIR Motion to 

disable detection when the temperature measurement. In other words,

The PIR motion will blind one second in every one minute.

* Illumination Report:

When the Motion Detector detected or the Door/Window Contact state

changed,   the   device   will   unsolicited   to   send   the  “Sensor   Multilevel

Report” to the nodes in the group 1.

Sensor Type: Luminance (0x03)

Note:   To  disable  this   functionality   by  setting   the  configuration   N0.5

bit4 to 1.

3

Содержание MT 02648

Страница 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Страница 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Страница 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Страница 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Страница 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Страница 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Страница 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Страница 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Страница 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Отзывы: