*** Illumination differential report ***

This function default is disabled, to enable this function by setting the

configuration NO.22 not to zero.

Enable  this  functionality,  the  device  will  measure  the  illumination  in

every one minute. And if the illumination is changed to plus or minus

the value (setting by the configuration NO.22), the device will report

illumination information to the nodes in the group 1. 

Caution 1

Enable this function will reduce the battery life about 15% 

~ 20%. And another issue is setting the differential value too small, it 

will cause report too frequency, shorter the battery life more.

Propose the setting differential value should not small than 10.

Caution 2

:

 If the configuration No.4 is setting to 0 or 100, this 

functionality is useless.

Caution 3

:

 Enable this functionality, it will cause the Motion Detector  

to disable detection when the illumination measurement. In other 

words, The Motion Detector will blind one second in every one minute.

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Door/window state report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 11.

Illumination level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 12.

Temperature report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 13.

Notice

:  The configuration NO. 10, 11, 12 and 13 could be setting to

zero to disable the auto report. And the configuration NO. 20 could

change the tick interval, the default value is 30, if setting to 1, that

means the minimum auto report interval will be one minute. And please

notice if setting this value to zero, that means disable all of the timing

report except the low battery detection.

Power Up Procedure

* Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* Motion Detector Warm Up

When  the  device  power  on,  the  Motion Detector  need  to  warm up

before the operation. The warm up time about 1 minute, the LED will

flash in every 2 seconds. After finish the procedure the LED will light

ON three times.

* NWI

When the device power on, the device will check is it already adding to

the network? If doesn't, it will auto start the NWI mode. The LED will

flash in every second and continue 30 seconds. Until timeout or the

device successful to inclusion by controller. The use can presses the

tamper key 3 times to abort the NWI mode.

* Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.

Before starting the procedure, please remove the front cover of the

device. Otherwise the hardware check will be failed.

Let the controller into the firmware update mode, and then press the

4

Содержание MT 02648

Страница 1: ...repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The ne...

Страница 2: ...imes within 1 5 seconds to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is...

Страница 3: ...03 Sensor Binary Report V2 Sensor Type Tamper 0x08 Sensor Value 0xFF Temperature Report When the Motion Detector detected or the Door Window Contact state changed the device will unsolicited to send t...

Страница 4: ...ry 6 hours report once in default It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configu...

Страница 5: ...Normal Mode OFF OFF Program Mode According to the configuration setting NO 5 to set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor fun...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...ntroller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group After finish the test a...

Страница 9: ...ans turn off illumination detected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none...

Страница 10: ...after door window opened to turn on the light Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def...

Страница 11: ...indow state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 1...

Страница 12: ...ASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Signal...

Отзывы: