background image

9

Never keep the trigger pulled on contact trip tools
when carrying or holding the tool. Death or a serious
puncture wound could occur if the contact trip bumps
something or someone.

Keep your hands and body away from the fastener
discharge area of the tool. Serious personal injury
could occur.

Do not  hold the tool against the work surface with
extra force.  Allow the tool to drive the fastener.

Do not use  the contact trip mechanism as a means of
discharging a fastener because:

1. It could result in personal injury
2. It could result in an accidental release of a

fastener.

3. It may cause damage to the mechanism.
4. It could result in improper placement of fastener

in work piece.

CONTACT TRIP

Your

 

ANF5 Angle Finish Nailer is a contact trip operated

tool.  When the operator depresses the contact trip safety
mechanism against the work surface and then pulls the
trigger, a fastener will be driven.

OPERATING A CONTACT TRIP TOOL:

1.

Requires finger to be off the trigger and the nose of
the tool to be placed on the work surface.

2.

The contact trip safety mechanism is then depressed
against the work surface and the trigger is pulled to
drive a fastener.

3.

The trigger is released after each fastener is driven.

4.

Move the tool to the next  desired fastener  location
and repeat the procedure above.

Check the operation of the contact trip safety
mechanism often.  Do not use the tool if  the
contact trip safety mechanism is not working
correctly.

CHECKING THE OPERATION OF
CONTACT TRIP SAFETY MECHANISM

1. Disconnect the air supply from the tool.

2. Remove all fasteners from the magazine.

3. Make sure the trigger and contact trip safety mechanism

move up and down without any sticking or binding.

4. Reconnect air supply to the tool.

5. Depress the contact trip safety mechanism against the

work surface without pulling the trigger. The tool must
not cycle. Do not  use the tool if a cycle occurs.

6. Hold the tool clear of the work surface. The contact

trip safety mechanism should return to its original
down position. Pull the trigger. The tool 

must not

cycle. Do not use the tool if a cycle occurs.

7. Depress  the contact trip safety mechanism against

the work surface. Pull the trigger. The tool 

must

cycle.

CONTACT  TRIP  SAFETY  MECHANISM

Make sure not to pull the trigger or depress the
contact  trip  safety  mechanism  when  connecting
the tool  to an air compressor. Serious personal
injury can occur if the tool cycles.

Содержание AFN5

Страница 1: ...is information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS PLEASE READ THIS MANUAL STEEL DRIVER SERIES Specifications MODEL AFN5 AIR INLET 1 4 NPT WEIGHT 5 lbs LENGTH 13 HEIGHT...

Страница 2: ...intenance 7 8 RecommendedHook up 8 Contact Trip Safety Mechanism 9 A Operating A Contact Trip Tool B Checking The Operation Of Contact Trip Safety Mechanism Loading The Tool 10 OperatingtheTool 10 11...

Страница 3: ...ct the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive satisfactory results from the Authorized Warranty...

Страница 4: ...plosion SAFETY GUIDELINES DEFINITIONS IMPORTANT SAFETY INFORMATION A HAZARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE Information that you should pay special attention to URGENT SAFETY INFORMATI...

Страница 5: ...f the contact trip safety mechanism is not working Death or a serious puncture could occur if the contact trip bumps something or someone while holding the tool with the trigger depressed Damage to th...

Страница 6: ...pressed and allow the tool to discharge a fastener into the air or through thin work materials HOW TO PREVENT IT HAZARD TO LOOK FOR Injury to self or others in the work area Pay attention to others in...

Страница 7: ...k oil level in the oiler daily See Figure 2 LUBRICATION AND MAINTENANCE NOTE Proper lubrication is the owner s responsibility Failure to lubricate the tool properly will dramatically shorten the life...

Страница 8: ...ings which will allow air to remain in the tool Serious personal injury could occur Do not use any type of flammable gases or oxygen as a power source for the tool Use filtered lubricated regu lated c...

Страница 9: ...rface and the trigger is pulled to drive a fastener 3 The trigger is released after each fastener is driven 4 Move the tool to the next desired fastener location and repeat the procedure above Check t...

Страница 10: ...lay b Never aim or point the tool at anyone The tool may contain fasteners c Always keep people and animals at a safe distance from the work area in case of accidental discharge of fasteners d Never p...

Страница 11: ...ect tool from air hose 2 Pull feeder shoe back into locked position 3 Remove jammed fasteners 4 Load good fasteners and unlock feeder shoe Step 3 Step 2 Step 1 CLEARING A JAM FROM THE TOOL 1 Add one d...

Страница 12: ...orrect size Fasteners are bent Fasteners coming apart in magazine Latch assembly weak or damaged Guide body groove damaged Door groove damaged Fasteners pusher system defective PROBLEM Air leaking at...

Страница 13: ...13 EXPLODED VIEW 24...

Страница 14: ...8 NSP 169 NSP 170 NSP 171 NSP 172 NSP 173 NSP 174 NSP 175 NSP 184 NSP 176 NSP 154 NSP 016 DESCRIPTION DESCRIPTION PART KITS Key Numbers 4 6 7 9 10 and 11 can only be purchased as part of NSK 006 Top R...

Страница 15: ...4 2 INTERCHANGE INFORMATION The DeVilbiss Angle Finishing Nailer AFN5 will accept Fasteners for Senco SFN2B SFN1 Fasco F31 BA50 F4 BA65 F3PBA 50 These Fasteners should be the same length and shank gau...

Страница 16: ...mber 1 800 888 2468 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorize...

Отзывы: