OPERATION
After the unit is installed and ready to use;
1. Attach air hose(s) to appropriate outlets (ball
valve not included).
2. Open main shut off valve upstream of filter.
3. Open appropriate ball valves or attach hoses to
supplied air respirator and/or air tools.
4. After use, shut off ball valve(s) and bleed off
residual air in hoses.
Note
The filter change indicator only operates when
air is flowing. It will always be green when there
is no flow.
MAINTENANCE
Risk of injury. Components under pressure.
Relieve air pressure before performing main-
tenance.
1. Before performing maintenance on unit, close
main shut-off valve located upstream of filter.
Bleed off residual air in unit.
2. To open filter, press button located on clamp ring
and rotate ring either clockwise or counterclock-
wise while pulling down on ring. The metal bowl
guard and plastic bowl can then be removed
from the filter head.
3. Frequency of element replacement will depend
upon air quality, temperature, air usage and con-
dition of the air piping. It is recommended to
change the element when it no longer removes
odors or when the red indicator is visible. Remove
the filter element by loosening counterclockwise.
4. Inspect o-ring for damage. Replace if necessary.
5. Inspect plastic bowl for signs of damage such as
cracks, crazing or deterioration. Replace if neces-
sary. See "Caution" above.
6. Before placing unit back into service, make sure
plastic bowl and metal bowl guard are properly
installed and securely locked in place.
DESCRIPTION
This 75 CFM filter is designed to remove oil vapor,
hydrocarbons and odors from a compressed air sys-
tem. It includes a .003 ppm/wt. aerosol filter element
and manual drain.
INSTALLATION
1. Be sure to read all "Warnings" and "Cautions" in
this manual and on the unit before installation or
using this equipment.
2. Install filter as close as possible to point where air
is being used. Install main air shut-off valve and
standard pipe union (supplied by user) upstream
of filter to allow maintenance to unit.
3. An appropriate coalescing filter must be located
upstream of the charcoal filter. Failure to due so
will result in the element becoming quickly satu-
rated and ineffective. We recommend a DeVilbiss
HAF-505 or HAF-515 Coalescing Filter.
4. Install unit with air flow through filter in direction
of arrow on top of unit.
5. Minimum 3/4" piping is recommended. Longer
pipe size will be required for high flow rates.
Avoid using fittings, couplings, etc. that restrict
air flow.
6. Mount filter in a vertical position.
7. Do not install filter in an application where the
pressure drop will exceed 20 psi. For example, a
quick opening valve located upstream from the
filter could cause a momentary pressure drop in
excess of 20 psi.
8. Maximum inlet pressure and operating tempera-
ture is: 150 PSIG (10.3 bar) and 150° F (65.6° C).
ACCESSORY
HAF-407 Bracket Assembly Kit – Used with HAF-502, HFRL-
508, HAF-505, HAF-517, HAF-518 and 13-0041 (HAF-500).
WARRANTY
This product is covered by DeVilbiss' 1 Year Limited Warranty.
DeVilbiss Sales and Service: www.devilbiss.com
DeVilbiss
DeVilbiss has authorized distributors throughout the world. For technical
assistance or the distributor nearest you, see listing below.
U.S.A./Canada Customer Service Office:
195 Internationale Blvd., Glendale Heights, IL 60139
Toll-Free Telephone: 1-800-992-4657 (U.S.A. and Canada only)
Toll-Free Fax: 1-888-246-5732
DeVilbiss Automotive Refinishing
DeVilbiss has authorized distributors throughout the world.
For equipment, parts and service, check the Yellow Pages
under “Automotive Body Shop Equipment and Supplies.”
For technical assistance, see listing below.
U.S.A./Canada Customer Service Office:
11360 S. Airfield Road, Swanton, OH 43558
Toll-Free Telephone: 1-800-445-3988 (U.S.A. and Canada only)
Toll-Free Fax: 1-800-445-6643
6/14 © 2014 DeVilbiss All rights reserved. Printed in U.S.A.