background image

SB-2-163-M  (11/2014)

7 / 8

NOTES

Содержание EGA-503

Страница 1: ... and tighten Adjust incoming air pressure to gun to achieve desired spray results Note To minimize overspray only use as much pressure as required to atom ize material PREVENTIVE MAINTENANCE To clean fluid passages remove excess material at source then flush with a suit able solvent To clean air cap and fluid tip brush with a stiff bristle brush If necessary use a broom straw or toothpick Never us...

Страница 2: ...ing sprayed and its concentration This spray gun spray pistol has aluminum passages and cannot be used with these solvents Aluminum is also widely used in other spray application equipment such as material pumps regulators valves etc Check all other equipment items before use Read the label or data sheet for the material you intend to spray If in doubt as to whether or not a coating or cleaning ma...

Страница 3: ...usekeeping in the U S these are OSHA Sections 1910 94 and 1910 107 and NFPA 33 Wear eye protection General Safety Solvent Spray Misuse All spray guns spray pistols project particles at high velocity and must never be aimed at any part of the body Never exceed the recommended safe working pressures for any of the equipment used The use of non recommended or non original accessories or spare parts m...

Страница 4: ...ing Gland 1 15 Fluid Needle included with Item 4 1 16 AG 7 K5 Needle Spring Kit Kit of 5 1 17 AG 16 Fluid Needle Adjusting Screw 1 18 EGA 441 Air Valve Assy 1 19 AG 46 K3 Lock Nut Kit of 3 1 20 EGA 9 K5 Stem Kit of 5 1 21 SST 3008 K5 Ball Kit of 5 1 22 C 104 K5 Spring Kit of 5 1 23 GD 36 K5 Spring Retainer Kit of 5 1 24 EGA 5 K6 Air Valve Plunger Kit of 6 1 1 A quantity of necessary parts is inclu...

Страница 5: ...ough Open needle adjusting screw Excessive overspray Too much atomization air pressure Reduce pressure spray mist Gun too far from work surface Adjust to proper distance Improper stroking arching gun motion too fast Move at moderate pace parallel to work surface Dry Spray Air pressure too high Decrease air pressure Gun tip too far from work surface Adjust to proper distance Gun motion too fast Slo...

Страница 6: ...sting Valve HAV 501 shown HAV 500 does not have pressure gauge Use to control air usage at gun HARG 510 Air Regula tor Use to maintain nearly constant outlet pres sure despite changes in inlet pressure and downstream flow Millennium 3000 Twin Cartridge Paint Spray Respirator NIOSH Certified for respiratory protection in atmospheres not immediatelydangerous to life 29 3100 Scrubs Hand Cleaner Towel...

Страница 7: ...SB 2 163 M 11 2014 7 8 NOTES ...

Страница 8: ...1 111 Fax 44 0 1202 573 488 China www finishingbrands com cn mkt finishingbrands com cn Tel 8621 3373 0108 Fax 8621 3373 0308 Mexico Industrial Finishing www finishingbrands com mx sales finishingbrands com mx Tel 011 52 55 5321 2300 Fax 011 52 55 5310 4790 France www finishingbrands eu info finishingbrands eu Tel 33 0 475 75 27 00 Fax 33 0 475 75 27 59 Japan www ransburg co jp binks devilbiss ran...