DEVIreg™ Smart
Installation Guide
8
4
Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall
(typically 80-170 cm.).
The thermostat should not be placed in wet rooms.
Thermostat must be placed outside zone 3. Place it
in an adjacent room and use floor sensor only.
Always place the thermostat according to local
regulation on IP classes.
Do not place the thermostat on the inner side of a
poorly insulated exterior wall.
Always install the thermostat at least 50 cm from
windows and doors, due to draft, when using regu-
lation in: floor and room mode or room alone mode.
Do not place the thermostat in a way that it will be
exposed to direct sunlight.