DEVIreg™ Smart
9
Installation Guide
Note:
A floor sensor is recommended in all floor
heating applications and
mandatory
to thin mats
and under wooden floors to reduce the risk of over-
heating the floor.
• Place the floor sensor in a protecting plastic conduit
in the floor construction in an appropriate place,
where the floor is not exposed to sunlight or draft
from door openings.
• Equally distant and >2 cm from the heating cables
on both sides.
• The conduit should
be flush with the floor
surface, countersink
the conduit if neces-
sary and possible.
• Route the conduit to
the connection box.
• The bending radius of the conduit must be min 50
mm.
1
2
≥