E-6
11. Measure dimension A of the test print.
Specifications
A4
: 20 ± 2.0 mm
Letter
: 11.2 ± 2.0 mm
12. If dimension A falls outside the specified range,
perform the following adjustment procedure.
13. Slide out the drawer and loosen the two indi-
cated screws.
If dimension A is more than the specified range,
move the guide plate in the direction of the arrow.
If dimension A is less than the specified range, move
the guide plate in the direction of the arrow.
14. After the adjustment has been made, produce
another test print and measure dimension A
again.
15. After the adjustment has been made, tighten the
screws which has been loosened in step 13.
VI. Affixing the tray label/paper size label
Affix the tray label or paper size label at the location
shown in the illustration.
Note:
If both are to be affixed, the tray label should be on
the upper side and the paper size label on the
lower side.
A3PFIXC025DA
A
Exit direction
A3PFIXC008DA
Screw
A3PFIXC022DA
A3PFIXC023DA
A3PFIXC024DA