background image

E-6

11. Measure dimension A of the test print.

Specifications
A4

: 20 ± 2.0 mm

Letter

: 11.2 ± 2.0 mm

12. If dimension A falls outside the specified range, 

perform the following adjustment procedure.

13. Slide out the drawer and loosen the two indi-

cated screws.

If dimension A is more than the specified range, 
move the guide plate in the direction of the arrow.

If dimension A is less than the specified range, move 
the guide plate in the direction of the arrow.

14. After the adjustment has been made, produce 

another test print and measure dimension A 
again.

15. After the adjustment has been made, tighten the 

screws which has been loosened in step 13.

VI. Affixing the tray label/paper size label

Affix the tray label or paper size label at the location
shown in the illustration.

Note:

If both are to be affixed, the tray label should be on
the upper side and the paper size label on the
lower side.

A3PFIXC025DA

A

Exit direction

A3PFIXC008DA

Screw

A3PFIXC022DA

A3PFIXC023DA

A3PFIXC024DA