bizhub PRO C6500
21. FUSING SECTION
107
Theory of Operation Ver1.0 Sep.2006
21.3.4
Protection against abnormality
• When the temperature sensor /1 (TEMS/1), /2 (TEMS/2), /3(TEMS/3), /4 (TEMS/4) is over the prescribed
temperature for a specified time period, it is judged as a high temperature error and the main relay (RY1) is
turned off, then the product is stopped after the first transfer, second transfer and fusing pressure are
stopped/released.
• When the temperature sensor /1 (TEMS/1), /2 (TEMS/2), /3 (TEMS3), /4 (TEMS/4) detect a temperature
of under -50 °C continuously for a specified time period, it is judged as a low temperature error and the
main relay (RY1) is turned off, then the product is stopped after the first transfer, second transfer and fix-
ing pressure are stopped/released.
• The thermostat /1 (TS1), /2 (TS2) shut down the power line to the fusing heater lamp /1 (L2), /2 (L3), /3 (L4)
at 190
±
7 °C.
• The thermostat /3 (TS3) shuts down the power line to the fusing heater lamp /4 (L5) at 160
±
7 °C.
• When the fusing temperature abnormality occurs, the relay-off status is maintained by latch (SC latch) and
an error message appears on the touch panel.
• After troubleshooting the cause of the error, the SC latch must be released by the software DipSW3-1.
a03ut2c082ca
CBR/1
NF
L2
TS2
TS1
TS3
RY
drive
section
Control section
AC
drive
section
CBR/2
RY/1
ACDB
PRCB
L3
L4
L5
TEMS/1
TEMS/2
TEMS/3
TEMS/4
Содержание ineo+ 6500
Страница 1: ...Dynamic balance www develop de ineo 6500 Service Manual Theory of Operation ...
Страница 25: ...C 6 Blank Page ...
Страница 26: ...SERVICE MANUAL 2006 09 Ver 1 0 Theory of Operation Main body C6500 ...
Страница 41: ...4 PAPER PATH 10 Theory of Operation Ver1 0 Sep 2006 bizhub PRO C6500 Blank page ...
Страница 164: ...SERVICE MANUAL 2006 09 Ver 1 0 DF 609 Theory of Operation ...
Страница 167: ...DF 609 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 173: ...3 PAPER PATH 6 Theory of Operation Ver1 0 Sep 2006 DF 609 Blank page ...
Страница 198: ...SERVICE MANUAL 2006 09 Ver 1 0 PF 601 HT 504 Theory of Operation ...
Страница 201: ...PF 601 HT 504 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 232: ...SERVICE MANUAL 2006 09 Ver 1 0 LU 202 HT 503 Theory of Operation ...
Страница 235: ...LU 202 HT 503 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 262: ...SERVICE MANUAL 2006 09 Ver 1 0 RU 503 504 Theory of Operation ...
Страница 265: ...RU 503 504 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 281: ...4 CONVEYANCE SECTION 16 Theory of Operation Ver1 0 Sep 2006 RU 503 504 Blank page ...
Страница 282: ...SERVICE MANUAL 2006 09 Ver 2 0 FD 501 Theory of Operation ...
Страница 299: ...3 PAPER PATH 14 Theory of Operation Ver2 0 Sep 2006 FD 501 Blank page ...
Страница 342: ...SERVICE MANUAL 2006 09 Ver 2 0 LS 501 502 Theory of Operation ...
Страница 345: ...LS 501 502 CONTENTS ii Theory of Operation Ver2 0 Sep 2006 Blank page ...
Страница 351: ...3 PAPER PATH 6 Theory of Operation Ver2 0 Sep 2006 LS 501 502 Blank page ...
Страница 376: ...SERVICE MANUAL 2006 09 Ver 2 0 FS 503 Theory of Operation ...
Страница 421: ...8 MAIN TRAY SECTION 42 Theory of Operation Ver2 0 Sep 2006 FS 503 Blank page ...
Страница 422: ...SERVICE MANUAL 2006 09 Ver 1 0 FS 607 Theory of Operation ...
Страница 481: ...8 FOLDING SADDLE STITCHING TRI FOLDING SECTION 56 Theory of Operation Ver1 0 Sep 2006 FS 607 Blank page ...
Страница 482: ...SERVICE MANUAL 2006 09 Ver 1 0 PI 502 Theory of Operation ...
Страница 485: ...PI 502 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 498: ...SERVICE MANUAL 2006 09 Ver 1 0 PK 512 513 Theory of Operation ...
Страница 501: ...PK 512 513 CONTENTS ii Theory of Operation Ver1 0 Sep 2006 Blank page ...
Страница 518: ...SERVICE MANUAL 2006 09 Ver 2 0 SD 501 Theory of Operation ...