![Devatec ElectroVap CMC Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/devatec/electrovap-cmc/electrovap-cmc_technical-manual_2488613019.webp)
RS485 data link (option)
CHARACTERISTICS :
RS 485 : 2 wires half duplex (+GND) Max. length = 1200 meters
(4,000 ft)
.
Biais : 620 Ohm pull up & Pull Down ( Selection by switch)
Terminaison : 120 Ohm ( selection by switch )
Protocol : JBUS or MODBUS.
(asynchrone data of 8 bits, without
parity bit, 1 stop bit, CRC)
Speed : 1200, 2400, 4800, 9600 bauds.
Dimensions : 95 x 50 mm.
The connecting cable is to be plugged onto connector X13 of the
main board ref : 50010
1
/ 0
4
.
Galvanic insolation (option)
This feature permits a galvanic isolation of the regulation signal from the humidifier : the circuits are
separated by an optical device.
This module is to be installed on a Din rail outside the humidifier.
X3
X2
+
-
2
1
19
20
18
X1
: 230 Vac 50-60Hz. supply
X1
X2:
0-10V outlet vto CMC
humidifier (the humidifier must be
commissioned in 0-10v regulation)
X3:
Regulator inlet signal (0-10V /
0-20V / 4-20mA)
Configurate the above mentioned
dip switch.
0 – 10V regulator
4 – 20 mA regulator
0 – 20V regulator
ON
Electrical installation
17
Electro
V
ap
C
MC
Wiring scheme
Содержание ElectroVap CMC
Страница 1: ......
Страница 22: ...ELMC 1 2 internal wiring Electrical installation 20 ElectroVap CMC Special US wiring scheme ...
Страница 23: ...ELMC 3 4 internal wiring Electrical installation 21 ElectroVap CMC Special US wiring scheme ...
Страница 24: ...ELMC 1 5 2 5 internal wiring Electrical installation 22 ElectroVap CMC Special US wiring scheme ...
Страница 28: ...ElectroVap CMC MAINTENANCE LIST TYPE CMC DETAILED MAINTENANCE WORK DATE NEXT DATE ON Maintenance 26 ...
Страница 29: ...ElectroVap CMC MAINTENANCE LIST TYPE CMC DETAILED MAINTENANCE WORK DATE NEXT DATE ON Maintenance 27 ...
Страница 30: ...ElectroVap CMC Drilling template for steam pipe ...