Electrical system
Service and maintenance
© 2007
61
6
reading indicates battery’s state of charge. The
acid temperature when measuring should be 20
°C if possible.
z
Check the acid level before recharging.
z
Screw in caps.
Removing the battery
z
Always disconnect the minus pole first when re-
moving the battery. Otherwise there is a danger
of short-circuit!
z
Remove the fastenings and take out the battery.
Charging the battery
z
Unscrew caps.
z
Charge the battery with a conventional battery
charger. Observe the manufacturer specifica-
tions!
z
Screw in caps.
Installing the battery
z
Insert new or charged battery and attach the fas-
tenings.
z
Clean the terminals and battery poles with fine
emery paper.
z
Connect the plus pole first and then the minus
pole. Otherwise there is a danger of short-circuit!
Make sure the terminals have good contact.
Tighten clamp bolts hand-tight.
z
Grease the assembled terminals with an acid-
Acid density [kg/ l]
Charge
status
Measure
Normal
Tropical
1,28
1,23
good
none
1,20
1,12
half
charge
1,12
1,08
empty
charge
free, acid-resistant grease.