Implemented protocols in UNIGATE® EL
Deutschmann Automation GmbH & Co. KG
45
UNIGATE
®
fieldbus gateway UNIGATE
®
EL - DeviceNet
™
V. 1.0
22.6.17
15.3.4 TCP (client)
Configuration: (EL) IP Address Target: >0
During startup (Power ON) the UNIGATE
®
tries to establish a TCP/IP connection with the remote
participant configured under the IP Address Target.
As long as the participant is not available in the network, the UNIGATE
®
tries to connect to the
server cyclically (every 17 ms). The Power/State LED flashes green.
If the participant is started as server, the UNIGATE
®
changes to data exchange state.
(Power/State LED = bright green)
If the server is stopped, the LED changes to flashing, the UNIGATE
®
leaves data exchange
state.
.
Note: If the cable is pulled during a TCP/IP connection and the UNIGATE
sends a message to the TCP/IP server, it may take up a few seconds till
the status changes from Data Exchange (Power / State LED = bright
green). The UNIGATE tries to establish a connection (Power / State LED =
flashing green).
If the connection is re-established, the connection is established again
after 5 seconds.