Error messages
9.4 Error number 200-299 (terminal error)
The following errors occur only on terminals (or if using cam controls of the LOCON 24, 48, 64
Series as a terminal).
Error No. Significance
Remarks
210
RX overflow error
Receive buffer overflow
211
TX overflow error
Transmit buffer overflow
212
TX change ID error
Error changing the ID
213
Timeout accessing LCD-display
Acknowledge the error. If the error occurs again, the unit
must be returned, specifying the information described in
chapter "Returning a unit"
220
Timeout connecting to cam control
221
Incorrect data record on transmission
to cam control
222
Checksum error on reception from
cam control
223
Checksum error on transmission to
cam control
224
Unknown command on transmission
to cam control
230
Incorrect configuration data record or
not possible to configure the cam
control
231
Incorrect initialisation data record
240
DICNET transmit error
241
DICNET receive error
242
Duplicate device number in DICNET
or connection problems
Assign a different device number.
Check for cable discontinuity, short circuit, non-twisted
cable....
243
Too many terminals in network (max.
3 allowed)
Reduce to 3 terminals
244
Max. 1 external terminal in the case
of multiple-axis version of the
LOCON 32
251
Internal error
252
Unknown command
Internal error
253
Checksum error detected by the cam
control
Internal error