8.6.1 Timing diagram
Picture 11:
Timing diagram - idle time compensation
8.7 Function of the idle time compensation
All mechanical circuit components which are usually connected to a cam control (e. g.: flood-
gates, magnetic valves...) feature idle time that means, between accessing the circuit component
and the mechanical reflex lies a constant time, the idle time.
The compensation of this idle time depends on the speed of the cam control.
The following processes of idle time compensation are possible:
•
path-dependent idle time compensation (standard process in every Deutschmann cam control)
•
time-controlled idle time compensation
•
direct idle time compensation (without dynamics brake)
Each of the above-mentioned methods has its advantages and disadvantages and is suitable
better or worse for a defaulted application.