Dehum
Parameter
Indications
Comments
Dehum Ratio
80-90
% CFM in dehumidification
Active Low
No , Yes
If DH input is active-low
Fan
Parameter
Indications
Comments
Cont Fan Ratio
0-100, FC*
% CFM when fan on
Rise
20-80, FC*
Temperature rise (°F)
Autobackup
Parameter
Indications
Comments
Enabled
No , Yes
If autobackup is enabled
Wait Time
0-120, FC*
Wait time before autobackup (min)
Update Delay
0-30, FC*
Time before updating autobackup command (sec)
Set PT Offset
0.0-3.5, FC*
Minimum offset with setpoint for autobackup (°F)
Rise
20-80, FC*
Temperature rise (°F) for autobackup
System
Parameter
Indications
Comments
AC/HP ON Delay
005-120, FC*
Fan delay after AC/HP start
AC/HP OFF Delay
005-240, FC*
Fan delay after AC/HP stop
Ratio Max Pwr
20-100, FC*
% of max. power of the furnace
Reset
Parameter
Indications
Comments
Factory Values
No , Yes
Reset furnace settings to factory defaults
*
FC
values will be shown if a more precise value has been configured at the furnace control (refer to the Supreme
furnace manual).
Alizé Heat Pump User Menus
Status
Parameter
Indications
Comments
Comp Speed
XX Hz
Compressor frequency
Fan Speed
XXX RPM %
Outdoor fan speed
Coil Temp
XX dF %
Indoor coil temperature (°F)
Tube Temp
XX dF %
Outdoor coil temperature (°F)
Comp Temp
XX dF %
Compressor discharge temperature (°F)
Version
X_X_X
Interface board firmware version
CFM/TON
Parameter
Indications
Comments
Heat CFM/TON
250-750
CFM/TON in heating
Cool CFM/TON
250-750
CFM/TON in cooling
Dry CFM/TON
250-750
CFM/TON in dehumidification
Defrost
Parameter
Indications
Comments
Defrost Fan %
0-100
% Fan during defrost
Defrost Heat
No , Yes
Use aux. heating during defrost.
If yes, the
Defrost Fan %
option will set the heat % of the furnace.
Reset
Parameter
Indications
Comments
Factory Values
No , Yes
Reset settings to factory defaults
26