Chinook Gas Furnace User Menus
Main Menus
Status
Used to display equipment information
Fault History
Display info. on last 6 error codes
2 Week History
Display operating info. of last 2 weeks
Life History
Display total operating info.
Unit Info
Display model and serial numbers
Setup
Adjustable settings
Status 1
Parameter
Indications
Comments
Main Limit
Closed , Open
Main limit control status
MRLC Input
Closed , Open
Main reset limit control status
HALC Input
Closed , Open
Heat assist limit control status
IDM Output
Off , Lo , Hi
Inducer output status
Furn Lo Pr Sw
Closed , Open
Low pressure switch status
Furn Hi Pr Sw
Closed , Open
High pressure switch status
Gas VLV Prcnt %
XXX %, Off
Gas valve % open
Gas VLV Relay
Lo , Hi , On, Off
Gas valve control output status
Flame
Off , Marginal ,
Status of flame sensor
Good , Unexpected
Blower CFM
CFM XXXX
Furnace blower CFM
Status 2
Parameter
Indications
Comments
Mod Heat ,
Mode
Lo Heat ,
Operating mode of the system
Hi Heat ,
AC1, AC2, Fan, HP1, HP2,
Off
Motor Mfgr
Regblt, Emerson
Blower motor manufacturer
Motor RPM
RPM
Blower motro RPM
Maximum CFM
CFM XXXX
Maximum CFM blower provides
Temp Rise
NA, XXXF
Temp. diff. between supply and return
Return Temp
XXXF, FLT
Return air temp. (if installed)
Supply Temp
NA (if disabled) ,
Supply air temp. (if installed and enabled)
XXXF, FLT
HUM Output
On , Off
Humidifier output relay status
EAC Output
On , Off
Electronic air cleaner output relay status
Fault History
Fault Code
Fautl Occurred
Comments
XXXXXXXXXXXXXXX
Days XX
Displat up to 6 faults;
Days indicates how many days ago the fault occured
Clear Faults
No , Yes
2 Week History
Parameter
Indications
Comments
2wk Lo HT Hrs
XXX
2 Week Low Heat Hours of Operation
2wk Lo HT Cycls
XXXX
2 Week Low Heat Cycles
2wk Hi HT Hrs
XXX
2 Week Low Heat Hours of Operation
2wk Hi HT Cycls
XXXX
2 Week Low Heat Cycles
2wk Y1 Hrs
XXX
2 Week 1st Stage Cooling/Heat Pump Hours of Operation
2wk Y1 Cycles
XXXX
2 Week 1st Stage Cooling/Heat Pump Cycles
2wk Y2 Hrs
XXX
2 Week 2nd Stage Cooling/Heat Pump Hours of Operation
2wk Y2 Cycles
XXXX
2 Week 2nd Stage Cooling/Heat Pump Cycles
2wk G Hrs
XXX
2 Week Blower Hours of Operation
2wk G Cycles
XXXX
2 Week Blower Cycles