Life History
Parameter
Indications
Comments
Total Days Pwrd
XXXX
Total days control has been powered
Lo HT Hrs
XXXXXX
Low Heat Hours of Operation
Lo HT Cycles
XXXXXX
Low Heat Cycles
Hi HT Hrs
XXXXXX
Low Heat Hours of Operation
Hi HT Cycles
XXXXXX
Low Heat Cycles
Y1 Hrs
XXXXXX
1st Stage Cooling/Heat Pump Hours of Operation
Y1 Cycles
XXXXXX
1st Stage Cooling/Heat Pump Cycles
Y2 Hrs
XXXXXX
2nd Stage Cooling/Heat Pump Hours of Operation
Y2 Cycles
XXXXXX
2nd Stage Cooling/Heat Pump Cycles
G Hrs
XXXXXX
Blower Hours of Operation
Unit Info
Parameter
Indications
Comments
Model Number
XXXX-XXXXXXXXXXXXXXX
Unit model number
Serial Number
XXXXXXXXXXXXXXXXXXX
Unit serial number
Software Vers
XXXXXX
Control software version
Setup
Parameter
Indications
Comments
Heat Rise Adjust
55F, 65F
Adjust heat temperature rise
Min Heat Adj %
-15, -7, 0, 7, 15
Airflow adjustments at 40% firing rate
Max Heat Adj %
-15, -7, 0, 7, 15
Airflow adjustments at 100% firing rate
Supply Air Sens
On , Off
If sensor is installed, turn on
Reset All Dflts
No , Yes
Reset furnace settings to factory defaults
Dipswitch *
DIP
Indications
Comments
Cool Airflow
XXXXCFM
Airflow setting
Heat Rise %
Nom, Nom+10
Temperature rise setting
Min Heat Adj %
-15, -7, 0, 7, 15
Airflow adjustments at 40% firing rate
Max Heat Adj %
-15, -7, 0, 7, 15
Airflow adjustments at 100% firing rate
Fan Spd Select
Lo , Hi
Fan speed setting
AC-HP Adj
-10%, 0%, 10%
AC airflow setting
On-Demand Dehum
On , Off
Dehumidification setting
Test Mode
Off , 40% (70%), 100%
Test mode setting
AC HP Stg Mult
NA, 50%, 75%
Heat pump stage multiplier
* Dipswitch status is not required when system is set up for 4-wire communicatiions. It is only displayed when a
conventional 24V thermostat input is active.
Supreme Electric Furnace User Menus
Status
Parameter
Indications
Comments
CFM
XXXX CFM
Current airflow
CMD
XXX %
% of active electric elements
Version
X_X_X
Firmware version
AC/HP
1
Parameter
Indications
Comments
AC/HP 1/2 Tons
0-10, FC*
Heat pump size in 1/2 tons
Mode
EFF, CO %
Efficient or Comfort mode
CFM/TON
300-500, FC*
Airflow per ton
AC Y1 Ratio
70-90, FC*
%CFM 1st stage cooling
1
The items of this menu are locked or unused when connected to a communicating Alizé Heat Pump.
25