Air-to-water Heat Pump Split Versati
40
SPLIT TYPE
(e) Temperature Setpoint
The control is able to decide the temperature type and temperature range based on the current “
Clock Timer
”,
“
Floor config
”, “
T-water Ctrl.
”, and “
Ctrl. state
” settings. See the followings for more details.
If the set mode is “
Hot water
”, the temperature set point shows nothing, indicating there is no need to set “
T-water
out
” and “
T-room
” but only “
T- water tank
”. If the set mode “
Cool
” or “
Heat
”, then water tank temperature box will
show nothing, indicating there is no need to set “
T-water tank
”.
Ctrl.
state
Set Mode
Object
Range
Default
Accuracy
T-water
out
Cool
Water out
temperature for
cooling(WT-cool)
45-77°F
(7-25°C)
(Without
underfloor
coil)
64-77°F
(18-25°C)
(With underfloor
coil)
45°F(7°C)
(Without underfloor coil)
64°F(18°C)
(With underfloor coil)
1°F(1°C)
Heat
Water out
temperature for
heating(WT-heat)
High temp.
77-131°F
(25-55°C)
113°F(45°C)
1°F(1°C)
Low temp.
77-113°F
(25-45°C)
95°F(35°C)
1°F(1°C)
T-room
Cool
Room temperature
for cooling(RT-
cool)
64-86°F(18-30°C)
75°F(24°C)
1°F(1°C)
Heat
Room temperature
for heating(RT-
heat)
64-86°F(18-30°C)
68°F(20°C)
1°F(1°C)
3.2.2.13 Clock Timer
This function will make the unit run with certain modes in certain periods within a day based on the user’s actual
demand.
[Operation Instructions]
(1)
At the homepage, by pressing the Function key
access to the
FUNCTION
page, and then locate
where “
Clock timer
” is, after that, press OK key
to go to the
COLCK TIMER
setting page.
(2) At the
CLOCK TIMER
setting page, by the Left/Right key
select the desired parameter and then
by the Up/Down key
configure it.
(3)
When this setting is concerned about time value, by pressing the Function key no. 1
alternately
set the hour or minute values, and by pressing the Up/Down key
increase or decrease the
corresponding value which will be continuously changed by pressing and holding the key. (Unless otherwise
specified, all timer settings follow the similar way.)