INTRODUCTION
This multiposition Category IV condensing furnace is
CSA design certified direct vent (2 pipes) and non-direct
vent (1 pipe). The furnace is factory shipped for use with
natural gas. The furnace can be converted in the field
for use with propane gas when a conversion kit is used
(B40574-03)
This furnace is designed for minimum continuous return
air temperature of 60 °F (16 °C) or intermittent operation
down to 55 °F (13 °C) such as when used with a night
setback thermostat.
Return air temperature must not
exceed 80 °F (27 °C). Failure to follow these return
air temperature limits may affect reliability of heat
exchangers, motors, and controls.
2.1
CODES AND STANDARDS
Follow all national and local codes and standards in
addition to these instructions.
The installation must
comply with regulations of the serving gas supplier, local
building, heating, plumbing, and other codes. In absence
of local codes, the installation must comply with the
national codes listed below and all authorities having
jurisdiction. In the United States and Canada, follow all
codes and standards for the following:
Table 1 – Codes and Standards
TOPIC
USA
CANADA
Safety
National Fuel Gas
Code (NFGC) NFPA
54-2009/ANSI
Z223.1
and
the
Installation
Standards,
Warm
Air
Heating
and
Air
Conditioning
Systems
ANSI/NFPA 90B
National
Standard
of Canada, Natural
Gas and Propane
Installation
Code
(NSCNGPIC)
CAN/CSA B149.1
General
installation
NFGC
and
the
NFPA
90B.
For
copies,
contact
the
National
Fire
Protection
Association
Inc.,
Battery
march
Park, Quincy, MA
02269; or for only
the NFGC contact
the
American
Gas
Association,
400
N.
Capitol,
N.W.,Washington
DC 20001
NSCNGPIC.
For
a
copy,
contact
Standard
Sales,
CSA
International,
178
Rexdale
Boulevard,
Etobicoke (Toronto),
Ontario, M9W 1R3,
Canada
Combustion
and
and
air
ventilation
Section
9.3
of
the
NFPA54/ANSI
Z223.1
Air
for
Combustion
and
Ventilation
Part
8
of
the
CAN/CSA
B149.1,
Venting
Systems
and Air Supply for
Appliances
Duct systems
Air Conditioning Contractors Association
(ACCA) (Manual D), Sheet Metal and
Air Conditioning Contractors National
Association (SMACNA), or American
Society of Heating, Refrigeration, and
Air Conditioning Engineers (ASHRAE).
Acoustical
lining
and
fibrous
glass
duct
current edition of SMACNA, NFPA 90B
as tested by UL Standard 181 for Class I
Rigid Air Ducts.
Gas piping and
pipe pressure
testing
NFPA
54/ANSI
Z223.1
NFGC;
Chapters 5, 6, 7,
and 8 and national
plumbing codes.
CAN/CSA-B149.1,
Part 6
Manufactured
Mobile
housing
Manufactured
Home Construction
and
Safety
Standard,
Title
24 CFR, Part 3280
or
The
Standard
for
Manufactured
Home
Installations
ANSI/NCS A225.1
Canadian Standard
for
Series
M92
Mobile
Homes,
CAN/CSA Z240MH
Electrical
connections
National
Electrical
Code
(NEC)
ANSI/NFPA 70
Canadian Electrical
Code CSA C22.1
Venting
Part
7,
Venting
of
equipment,
latest edition of the
National Fuel Gas
Code
NPFA
54,
90A and 90B ANSI
Z223.1-
CAN/CSA-B149.1-
05 latest edition
7
Содержание CC15-M-V
Страница 18: ...Figure 17 Wiring Diagram 18...
Страница 23: ...Figure 25 Direct vent clearance 23...
Страница 24: ...Figure 26 Other than Direct vent clearance 24...
Страница 34: ...12 PART LIST Figure 27 Exploded view...
Страница 35: ...Figure 28 Exploded view continued...
Страница 36: ...Table 19 Part list Chinook Compact...
Страница 37: ...Table 20 Part list continued...
Страница 38: ...13 NOTES 38...
Страница 39: ...39...
Страница 40: ...40...