background image

TECHNICAL GUIDE

95.5% SINGLE STAGE
GAS-FIRED RESIDENTIAL 
MULTI-POSITION GAS FURNACES

MODELS: TG9S

NATURAL GAS
40 - 130 MBH INPUT

Due to continuous product improvement, 
specifications are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional efficiency rating information can 
be found at www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

400991-YTG-B-0708

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION 

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation  in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.

WARRANTY

Lifetime limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
5-year limited parts warranty.

FEATURES

Easily applied in upflow, horizontal left or right, or
downflow installation with minimal conversion necessary.

Compact, easy to install, ideal height 33" tall cabinet.

Blower-off delay for cooling SEER improvement.

Easy access to controls to connect power/control wiring.

Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable
operation.

Low unit amp requirement for easy replacement
application.

Single wire twinning or staging feature available.

All models are convertable to use propane (LP) gas.

Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.

100% shut off main gas valve for extra safety.

4 speed, direct drive PSC motor.

24V, 40 VA control transformer and blower relay supplied
for add-on cooling.

Hi-tech tubular aluminized steel primary heat exchanger.

Secondary heat exchanger made of corrosion resistant
stainless steel materials.

Timed on, adjustable off blower capability for maximum
comfort.

Blower door safety switch.

Solid removable bottom panel allows easy conversion.

Airflow leakage less than 1% of nominal airflow at
ductblaster conditions.

No knockouts to deal with, making installation easier.

Movable duct connector flanges for application flexibility.

Quiet inducer operation.

Inducer rotates for easy conversion of venting options.

Fully supported blower assembly for easy access and
removal of blower.

External air filters used for maximum flexibility in meeting
customers IAQ needs.

Protection included from air intake, exhaust vent, or
condensate blockage.

Patent pending self priming internal condensate trap
design for easy installation.

Venting applications - may be installed as a either 2-pipe
(sealed combustion) or single-pipe vent (using indoor
combustion air.

No special vent termination required.

1/4 turn knobs provided for easy door removal.

Содержание TG9S

Страница 1: ...to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable operation Low unit amp requirement for easy replacement application Single wire twinning or staging feature available All models are convertable ...

Страница 2: ...13 TG9S060A10MP11 1000 A 14 1 2 13 3 8 11 3 4 118 TG9S060B12MP11 1200 B 17 1 2 16 3 8 13 1 4 122 TG9S080B12MP11 1200 B 17 1 2 16 3 8 14 3 4 126 TG9S080C16MP11 1600 C 21 19 7 8 16 1 2 136 TG9S080C22MP11 2200 C 21 19 7 8 16 1 2 139 TG9S100C16MP11 1600 C 21 19 7 8 18 1 4 142 TG9S100C20MP11 2000 C 21 19 7 8 18 1 4 145 TG9S120D16MP11 1600 D 24 1 2 23 3 8 21 3 4 153 TG9S120D20MP11 2000 D 24 1 2 23 3 8 2...

Страница 3: ...BR0614 For 14 1 2 cabinets S1 1BR0517 or 1BR0617 For 17 1 2 cabinets S1 1BR0521 or 1BR0621 For 21 cabinets S1 1BR0524 or 1BR0624 For 24 1 2 cabinets 1BR05xx series are galvanized steel filter racks 1BR06xx are pre painted steel filter racks to match the appearance of the furnace cabinet COMBUSTIBLE FLOOR BASE KIT For installation of these furnaces in downflow applications directly onto combustible...

Страница 4: ...232 1313 1291 1280 1250 1209 1207 1148 1055 937 Low 826 821 853 858 838 817 794 776 760 711 TG9S080C22MP11 High 2529 2435 2338 2256 2162 2041 1920 1794 1654 1501 Medium High 2166 2111 2070 2001 1927 1849 1719 1614 1499 1344 Medium Low 1697 1685 1664 1631 1586 1531 1466 1393 1315 1185 Low 1383 1377 1358 1336 1285 1244 1199 1147 1048 925 TG9S100C16MP11 High 1909 1880 1823 1776 1706 1637 1562 1474 13...

Страница 5: ...1209 Medium High 1543 1543 1516 1504 1477 1446 1382 1309 1202 1099 Medium Low 1238 1241 1243 1241 1252 1242 1201 1140 1074 967 Low 906 902 903 910 888 866 859 829 795 743 TG9S080C22MP11 High 2585 2492 2405 2321 2232 2137 2015 1902 1745 1577 Medium High 2098 2067 2036 1982 1928 1860 1767 1670 1549 1331 Medium Low 1619 1628 1614 1584 1545 1488 1424 1339 1216 1121 Low 1338 1347 1327 1301 1262 1199 11...

Страница 6: ... change without notice Printed in U S A 400991 YTG B 0708 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 400991 YTG A 0608 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 ...

Отзывы: