Table 7
Airflow data model with 1HP ECM motor
SW1- HEAT
DIP switch position
HEAT INPUT
(USGPH)
CFM with
SW3-ADJ
DIP switch position
A
CFM with
SW3-ADJ
DIP switch
position B
CFM with
SW3-ADJ
DIP switch
position C
A
(1=OFF, 2=OFF)
0.68
1160
1310
990
B
(1=ON, 2=OFF)
0.80
1340
1400
1140
C
(1=OFF, 2=ON)*
0.68
1000
1130
850
D
(1=ON, 2=ON)*
0.80
1160
1310
990
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with
SW3-ADJ
DIP switch position
A
CFM with
SW3-ADJ
DIP switch
position B
CFM with
SW3-ADJ
DIP switch
position C
A
(1=OFF, 2=OFF)
3.5
1050
1210
895
B
(1=ON, 2=OFF)
3.0
900
1035
765
C
(1=OFF, 2=ON)
2.5
750
865
640
D
(1=ON, 2=ON)
2.0
600
690
510
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with
SW3-ADJ
DIP switch position
A
CFM with
SW3-ADJ
DIP switch
position B
CFM with
SW3-ADJ
DIP switch
position C
A
(1=OFF, 2=OFF)
3.5
1400
1400
1260
B
(1=ON, 2=OFF)
3.0
1200
1320
1080
C
(1=OFF, 2=ON)
2.5
1000
1100
900
D
(1=ON, 2=ON)
2.0
800
880
720
SW4- DEALY
DIP switch position
HEAT INPUT
(USGPH)
PreRun
On-Delay
CFM Level - Time
ShortRun
On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
A
(1=OFF, 2=OFF)
0.68
13% - 45 sec.
19% - 60 sec
38% - 3 min.
B
(1=ON, 2=OFF)
0.80
13% - 45 sec.
19% - 30 sec
38% - 3 min.
C
(1=OFF, 2=ON)
All
13% - 45 sec.
100% - 0 sec
100% - 2 min.
D
(1=ON, 2=ON)
All
13% - 90 sec.
100% - 0 sec
100% - 2 min.
No adjustment
required
A/C size
PreRun
On-Delay
CFM Level - Time
ShortRun
On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
-
All
NO DELAY
NO DELAY
100% - 90 sec
OIL HEATING MODE
24 VAC input (R) on W only
CONTINUOUS FAN
24 VAC input (R) on G only
COOLING OR HEAT PUMP HEATING MODE
24 VAC input (R) to G, Y/Y2 and O (for cooling)
In Cooling - Dehumidification mode, with no 24 VAC input to DH, the CFMs are reduced by 15%.
The CFMs shown are reduced by 20% if there is 24 VAC input to Y1 (first stage cooling mode)
DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE
DELAY PROFILE FOR OIL HEATING MODE
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to
minimize the distributon of cool air in the system and then runs up to normal speed.
Off Delay is the time required to cool down the heat exchanger with low CFMs, to minimize cool
draft in the air distribution system.
* Alternate adjustment in oil-fired heating mode with higher temperature rise
Содержание AMP154SD
Страница 17: ...17 Figure 9 Furnace Dimensions ...
Страница 18: ...18 Figure 10 Wiring diagram 4 speed motor PSC ...
Страница 19: ...19 Figure 11 Wiring diagram variable speed motor ECM ...
Страница 20: ...20 Figure 12 Parts list with 4 speed motor PSC B500111A ...
Страница 22: ...22 Figure 13 Parts list with variable speed motor ECM B50112A ...