WARNING
!
4
LD3
Series
1.0
Introduction
•
Safety Signs and Labels
Safety Signs and Labels
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.
Read and understand all safety information and warnings in this manual before
installation, operation, and maintenance of the radiant tube heater system.
SER
VICE ACCESS
P
ANEL
CONTROLS & GAS V
AL
VE COMP
ARTMENT
1.
Disconnect gas & electricity
.
2.
Remove four (4) thumbscrews.
3.
Remove top cover
.
4.
Swing hinged panel downward.
KEEP
COVER IN PLACE. REMOVE FOR SER
VICE ONL
Y
.
SER
VICE ACCESS
P
ANEL
F
AN COMP
ARTMENT
1.
Disconnect gas & electricity
.
2.
Remove top cover (2 thumbscrews).
3.
Remove tsix (6) 1/4” screws.
4.
Lift and remove panel.
KEEP
COVER IN PLACE. REMOVE FOR SER
VICE ONL
Y
.
Top Panel
F/N: LLTCL006L/C/R
Clearance to Combustibles Label
Bottom Panel
F/N: LLLOGO32
Logo Label
!
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause property damage, injury
or death.
Read and understand the installation, operating
and maintenance instructions thoroughly before
installing or servicing this equipment.
12”
This heater must be installed and serviced by trained
gas installation and service personnel only.
This is
NOT
an explosion-proof heater.
DO NOT
install
in explosive environments. Where there is the
possibility of exposure to flammable vapors or dusts,
consult the local fire marshall, your insurance carrier or
authorities for approval of the proposed installation.
VENTING
. This heater must be properly vented
according to the manufacturer’s specifications.
WARNING
: Operation of this heater, when
not properly vented with an approved
system, can result in carbon monoxide
(CO) poisoning and possible death.
This heater requires
FRESH COMBUSTION AIR
for
safe operation and must meet all provisions of the
specified combustion and ventilation requirements.
GAS CONNECTION
. Allowances must be made for the
system to expand. A flexible gas connection of approved
type is required. Flexible stainless steel gas connectors
installed in one plane, without sharp bends, kinks or
twists is recommended. Consult manual for further
instructions.
WARNING
: Connector must be installed in a “C”
configuration. Use only the connector that was
furnished with the heater.
Gas Pipe
Gas Flex
Hose
Gas Flex Hose
Heater
Movement
45°
45°
3
F/N: LLAC023
Combustion Air
Connector Label
F/N: LLTB018 (Natural Gas)
F/N:
LLTB019 (Propane Gas)
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
F/N: LLV3EP1
120 V Input Label
F/N: LLV3EP14
Valve and PS Label
Back Panel