Question: It is not possible to
make external calls.
Check the connection between the
NTBA and the OpenCom 510.
In the
Configurator
, check whether
the external S
0
ports are configured
correctly (
PBX Configuration: S0
menu).
Question: The OpenCom 510 is
connected to an NTBA with a
multi-terminal configuration. Why
is it not possible to establish exter-
nal connections?
With the original factory setting, an
additional external S
0
port is set for
an NTBA in system configuration;
this additional port will be used first
to seize a trunk line.
Deactivate the corresponding S
0
port in the
Configurator
(
PBX Con-
figuration: S0
menu).
Question: One of the telephones
is not functioning at all.
Make sure the telephone has been
properly connected.
Check also whether the appropriate
port has been configured correctly in
the
Configurator
(
PBX Configura-
tion: Ports
menu).
Question: It is not possible to
make external calls with one of the
telephones.
Check whether a user is configured
for the telephone. Otherwise the
settings of the Guests user group are
valid for the telephone. To standard,
this user group has no external call
authorisation.
Make sure the user configured for
this telephone belongs to a user
group with external line access
(
Configurator
,
User Manager: User
groups
menu).
Check also whether the internal call
number of this telephone has been
configured for outgoing call distri-
bution (
Configurator
,
PBX Configu-
ration: Call Distribution
menu).