REPLACEMENT PARTS

The detector is not designed to be repaired in the field. If 

a problem should develop, refer to the “Troubleshooting” 

section. If it is determined that the problem is caused by 

an electronic defect, the device must be returned to the 

factory for repair.  

REPLACEMENT PARTS LIST

Part Number

Description

009208-002

oi

 Replacement kit for X52/X22/X98 (5 Reflector Plates) 

with Inspector Connector and Monitor

007307-002

Replacement 

oi 

Reflector Plate for X52/X22/X98 

(requires Inspector Connector to calibrate)

DEVICE REPAIR AND RETURN

Prior to returning devices, contact the nearest local 

Detector Electronics office so that a Return Material 

Authorization (RMA) number can be assigned. 

written statement describing the malfunction must 
accompany the returned device or component to 
assist and expedite finding the root cause of the 
failure.  When items are being returned, please note:

NOTE

Shipping personnel must be hazmat trained to 
pack, mark, and label the return package. Please 
consult your country-specific regulations.

Pack the unit properly. Always use sufficient packing 

material.  Where applicable, use an antistatic bag as 

protection from electrostatic discharge.

NOTE

Det-Tronics reserves the right to apply a service 
charge for repairing returned product damaged as 
a result of improper packaging.

Return all equipment transportation prepaid to the factory 

in Minneapolis.

NOTE 

It is highly recommended that a complete spare 
be kept on hand for field replacement to ensure 
continuous protection. 

NOTE 

Radioactive material is subject to regulation.  All 
products containing a source tube meet the definition 
of an “excepted package” for radioactive material 
under the US Department of Transportation (DOT), 
the International Air Transport Association (IATA), 
the International Civil Aviation Organization (ICAO), 
the International Maritime Dangerous Goods Code 
(IMDG), and any other specific hazardous material 
regulations from the country of source of return (TDG, 
RID, ADR, etc.). These units are classified as “UN2911, 
Radioactive Material, Excepted Package – Article.”  
Not applicable to model X5200G; not subjected to 
UN2911 Classification.

ORDERING INFORMATION

When ordering, please specify:
X5200, X5200G, or X5200M UVIR Flame Detector with 

Pulse Output
Refer to the X5200 Model Matrix below for details
Q9033 Mounting Arm is required:

 

– Q9033A for aluminum detectors only

 

– Q9033B for aluminum and stainless steel detectors

ACCESSORIES

Part Number

Description

000511-029

Converter RS485 to RS232

103881-001

Converter RS485 to USB

007819-001

W6300B1002 Serial Inspector Connector

 (Inspector Monitor software included)

007819-002

W6300B1003 USB Inspector Connector

 (Inspector Monitor software included)

009207-001

Flame Inspector Monitor CD

103922-001

Model 475 HART Communicator

102740-002

Magnet

008082-001

Magnet and Adapter for Extension Pole

007739-001

Magnet and Extension Pole

007240-001

Q1116A1001, Air Shield (AL)

007818-001

Q1118A1001 Aluminum Air Shield/Flange Mount (AL)

007818-002

Q1118S1001 Stainless Steel Air Shield/Flange Mount (SS)

009177-001

Q1120A1001 Paint Shield mounting ring (AL)

006097-001

Q1201 Laser

102871-001

Laser Battery, 3V Lithium (laser)

007255-001

Q1201C1001 X-Series Laser Holder (AL/Plastic)

007338-001

Q2000A1001 X-Series Weather Shield (AL)

007290-001

Q9033B Stainless Steel Mounting Arm Assembly is for 

aluminum and stainless steel detectors

007290-002

Q9033A Aluminum Mounting Arm Assembly is for aluminum 

detectors only 

011385-001

Q9033 Collar Attachment

101197-001

Stop Plug, 3/4” NPT, AL

101197-004

Stop Plug, 3/4” NPT, SS

101197-005

Stop Plug, M25, AL, IP66

101197-003

Stop Plug, M25, SS, IP66

010816-001

Stop Plug, 20 Pack, 3/4”NPT, AL

010817-001

Stop Plug, 20 Pack, 3/4”NPT, SS

010818-001

Stop Plug, 20 Pack, M25, AL, IP66

010819-001

Stop Plug, 20 Pack, M25, SS, IP66

103363-001

14 mm Hex Wrench (Steel)

103406-001

Screwdriver

001680-001

Window cleaner (6 pack)

107427-040

O-ring - Rear Cover (Viton) - black or brown

005003-001

1 oz grease for detectors (silicone-free)

104346-154

O-ring - Rear Cover (Fluorosilicone) - blue

012549-001

1 oz PTFE silicone-free lubricant

Содержание X5200

Страница 1: ...9 2 Rev 11 15 95 8547 Instructions UVIR Flame Detector with Pulse Output X5200 X5200G X5200M...

Страница 2: ...amage 8 Wiring Procedure 8 EOL Resistors 16 STARTUP PROCEDURE 16 Manual oi Test Output to Controller 16 Count Test Mode Output to Controller 16 FireAlarmTest Pulse Output to FireAlarm Panel 17 TROUBLE...

Страница 3: ...ors simultaneously detect the presence of a flame an alarm signal is generated The X5200 with pulse relay output is designed for use in controller based systems In addition to use in new systems it ca...

Страница 4: ...produce an alarm condition The detector signals a fault condition when less than half of the detection range remains This is indicated by the fault relay and is evident by the yellow color of the LED...

Страница 5: ...and other information with external devices The RS 485 uses Modbus protocol with the detector configured as a slave device DATA LOGGING Data logging capability is also provided Status conditions such...

Страница 6: ...onse is dependent on the detector s sensitivity setting arc rejection and time delay settings Other factors include distance type of fuel temperature of the fuel and time required for the fire to come...

Страница 7: ...avoided For example if IR radiation with an intensity that exceeds the fire threshold of the IR sensor should reach the detector as a flickering signal and if at the same time an electric arc welding...

Страница 8: ...zard Krypton gas and its radioactive isotope are inert and are not absorbed by the body No special handling measure or personal protection equipment is needed for the UVIR detectors Not applicable to...

Страница 9: ...area This will minimize the possibility of false alarms caused by activities outside the area requiring protection The detector must be mounted on a rigid surface in a low vibration area Dense fog rai...

Страница 10: ...ors the wiring and power supplies may not be adequate Consult the factory for assistance 13 1 33 4 10 6 27 0 4 0 10 2 4 0 10 2 3 0 7 6 3 0 7 6 4X 0 42 1 1 E2069 NOTE THIS ILLUSTRATION SHOWS THE DETECT...

Страница 11: ...nd and permanently isolate it from accidental contact with the case and or other conductors At the controller fire panel end connect the shield and power minus to chassis earth ground either directly...

Страница 12: ...ATA BUS 1 DATA BUS 2 DATA BUS 3 DATA BUS 4 DATA BUS 5 DATA BUS 6 DATA BUS 7 CHASSIS EARTH GND J1 7 J1 15 J1 5 J1 13 J1 6 J1 14 J1 8 J1 16 J1 9 J1 17 J1 10 J1 18 J1 11 J1 19 J2 R7404 CONTROLLER J1 10 T...

Страница 13: ...63 64 ZONE OUTPUT 1 ZONE OUTPUT 2 ZONE OUTPUT 3 ZONE OUTPUT 4 ZONE OUTPUT 5 ZONE OUTPUT 6 ZONE OUTPUT 7 ZONE OUTPUT 8 FIRE LOGIC A FIRE LOGIC B ALARM OUTPUT EXTERNAL RESET INHIBIT OUTPUTS INHIBITED F...

Страница 14: ...48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 ZONE OUTPUT 1 ZONE OUTPUT 2 ZONE OUTPUT 3 ZONE OUTPUT 4 ZONE OUTPUT 5 ZONE OUTPUT 6 ZONE OUTPUT 7 ZONE OUTPUT 8 FIRE LOGIC A FIRE LOGIC B ALARM OUTPU...

Страница 15: ...CTOR 7 2 1 19 22 2 1 19 22 X5200 DETECTOR 8 2 1 19 22 R7495 CONTROLLER NOT FM APPROVED J1 J2 A2146 NOTE IF THE POWER SUPPLY MINUS CANNOT BE CONNECTED TO CHASSIS EARTH GROUND CONNECT A 0 47 F 400 VDC N...

Страница 16: ...OR 8 2 1 19 22 R7405 CONTROLLER NOT FM APPROVED J1 J2 A2147 NOTE IF THE POWER SUPPLY MINUS CANNOT BE CONNECTED TO CHASSIS EARTH GROUND CONNECT A 0 47 F 400 VDC NON POLARIZED CAPACITOR BETWEEN J1 2 AND...

Страница 17: ...2 N O FIRE2 N C FIRE2 COM FAULT1 N O FAULT1 Vin Vin Vin 29 28 27 26 25 24 23 22 21 SPARE SPARE RS 485 A RS 485 B MAN Oi Figure 11 Ex d Wiring Option C2149 FIRE ALARM PANEL X5200 DETECTOR ALARM ALARM 2...

Страница 18: ...omplete system test including detector relays Generates fire alarm output MANUAL oiTEST Output to Controller 1 Place the keylock switch in the TEST position 2 Press the SELECT button to display the de...

Страница 19: ...mended for this purpose 6 Enable extinguishing equipment when the test is complete TROUBLESHOOTING WARNING The sensor module front half of the detector contains no user serviceable components and shou...

Страница 20: ...er cleaning remove and clean the oi plate using the oi Plate Removal and Replacement procedure IMPORTANT When used in extreme environments the reflective surface of the detector oi plate may eventuall...

Страница 21: ...ective Compliant SPECIFICATIONS OPERATING VOLTAGE 24 Vdc nominal 18 Vdc minimum 30 Vdc maximum Maximum ripple is 2 volts peak to peak For CSA compliance the power source must use a SELV Safety Extra L...

Страница 22: ...tant 18 Vdc minimum must be available at the detector For ambient temperatures below 10 C 14 F and above 60 C 140 F use field wiring suitable for both minimum and maximum ambient temperature THREAD SI...

Страница 23: ...tions from the country of source of return TDG RID ADR etc These units are classified as UN2911 Radioactive Material Excepted Package Article Not applicable to model X5200G not subjected to UN2911 Cla...

Страница 24: ...ce Tube X5200M UV IR Flame Detector with Molybdenum Tube TYPE MATERIAL A Aluminum S Stainless Steel 316 TYPE THREAD TYPE 4M 4 PORT METRIC M25 4N 4 PORT 3 4 NPT TYPE OUTPUTS 15 Relay and Pulse TYPE APP...

Страница 25: ...cription 102740 002 Magnet 007739 001 Magnet and Extension Pole 007290 001 Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 007290 002 Q9033A Aluminum Mountin...

Страница 26: ...ze Distance feet m Typical Response Time seconds n Heptane 1 x 1 foot 50 15 2 8 High Sensitivity UV Low Sens IR Hi Arc TDSA On Quick Fire Off Fuel Size Distance feet m Typical Response Time seconds n...

Страница 27: ...ogen lamp unmodulated 5 1 5 2 inch dia Heptane 5 1 5 2 500 w shielded quartz halogen lamp modulated 5 1 5 2 inch dia Heptane 5 1 5 2 1500 w electric quartz heater unmodulated 10 3 2 inch dia Heptane 5...

Страница 28: ...Quick Fire On Fuel Size Distance feet m Horizontal degrees Typical Horz Response Time seconds Vertical degrees Typical Vert Response Time seconds Methane 32 inch plume 7 5 2 2 45 45 0 9 0 2 45 30 0 1...

Страница 29: ...ncandescent lamp modulated 3 0 9 1 x 1 foot n Heptane 40 12 6 500 w halogen lamp unmodulated 3 0 9 1 x 1 foot n Heptane 40 12 1 500 w halogen lamp modulated 3 0 9 1 x 1 foot n Heptane 40 12 11 1500 w...

Страница 30: ...102740 002 Magnet 007739 001 Magnet and Extension Pole 007290 001 Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 007290 002 Q9033A Aluminum Mounting Arm As...

Страница 31: ...on protection increased safety e for use with the terminal compartment in type of explosion protection increased safety e They shall be IP66 IP67 rated suitable for the conditions of use and correctly...

Страница 32: ...fety e or flameproof enclosure d as applicable suitable for the conditions of use and correctly installed They shall maintain the degree of ingress protection IP66 IP67 for the apparatus Unused condui...

Страница 33: ...ly installed Unused entries shall be closed with suitable certified blanking elements The metal housing for the Ultraviolet Infrared UVIR flame detector type X5200 must be electrically connected to ea...

Страница 34: ...le Quantum Premier Safety System 95 8547 Corporate Office 6901 West 110th Street Minneapolis MN 55438 USA www det tronics com Phone 1 952 941 6665 Toll free 1 800 765 3473 Fax 952 829 8750 det tronics...

Отзывы: