Appendix - User info codes_02/2017
- 33 -
Type of
code
Code
no.
Description
Resolution procedure
Error
32
Tool display error
1- Board display malfunction.
2- Contact your Desoutter representative for support.
Error
34
Tool mem. err
1- The tool memory does not work properly.
2- Contact your Desoutter representative for support.
Error
35
Tool memory locked
1- The tool memory is locked to protect old data from rewriting.
2- Connect the tool to E-dock to retrieve old data.
Error
37
Tool trig err.
1- The tool trigger does not work properly.
2- Check and clean the trigger. If the problem occurs again, contact your
Desoutter representative for support.
Error
45
Anormal battery voltage
1- Anormal battery high voltage, check your battery.
2- This error can due to charger malfunction or end of life battery.
Error
47
Battery is too low
1- Battery is too low, check your battery.
2- If the problem occured again, change the battery with a new one.
Error
48
Battery type not allowed
1- Battery type not allowed.
2- Change your battery type or your configuration.
Error
200
Quick stop !
1- The quick stop has been activated
2- Check the Phoenix connector
Error
213
Drive Connect. Lost
1- Connection with the drive has been lost.
2- Reboot the controller.
3- If the issue remains, contact your Desoutter representative.
Error
216
Current high
1-Max current exceeded.
2-Contact your Desoutter representative for support
Error
217
Drive disabled
1-Drive disabled by external source.
2-Contact your Desoutter representative for support
Error
218
Drive power failure
1- Drive hardware failure.
2- Safety issue: contact your Desoutter representative for support
Error
219
Trig. safety fail.
1- Drive hardware failure.
2- Safety issue. Contact your Desoutter representative for support.
Error
220
Hardware trip
1- Drive hardware failure.
2- Safety issue. Contact your Desoutter representative for support.
Error
221
Drive check err.
1- Drive hardware failure.
2- Safety issue. Contact your Desoutter representative for support.
Error
222
Controller Too Hot
1- Heatsink too warm.
2- Let the controller cool down.
Error
223
Drive init error
1- Software failure.
2- Restart the controller.
3- If the problem occurs again, contact your Desoutter representative for
support.
Error
227
Motor stalled
1- Motor stalled (could be missing phase, wrong motortune or power
electronics failure)
2- Try once again, if the problem occurs again, contact your Desoutter
representative for support.
Error
228
Drive err.
1- Software failure
2- Restart the controller.
3- If the problem occurs again, contact your Desoutter representative for
support
Error
229
Err. ctrl. loop
1- Software failure.
2- Restart the controller.
3- If the problem occurs again, contact your Desoutter representative for
support.
Error
230
DC bus high
1- Max current exceeded. DC-bus voltage high
2- Contact your Desoutter representative for support
Error
231
DC bus too low
1- Power failure. DC-bus voltage low
2- Contact your Desoutter representative for support.
Error
232
Err. ID fieldbus
1- The Fieldbus module plugged in the controller cannot be run. It is not an
authorized Desoutter module.
2- Contact your Desoutter representative for more information.
Error
233
CVINET FIFO full
1- The CVINet result FIFO is full, the CVINet connection has been lost
2- Check the CVI3 Ethernet cable
3- Check CVI3 Ethernet configuration
4- Check if CVINet is running correctly
Содержание CVI3 Function
Страница 2: ......
Страница 5: ...Table of contents_02 2017 5...
Страница 27: ...Appendix I O and events_02 2017 27...
Страница 35: ...Appendix User info codes_02 2017 35...
Страница 43: ......
Страница 44: ...www desouttertools com Copyright 2017 More Than Productivity...