Appendix - User info codes _02/2017
- 28 -
Type of
code
Code
no.
Description
Resolution procedure
Info
1
Tubenut open
1-Tubenut tool is detected as open
Info
2
Tool connected
1- The tool is connected and correctly recognized by the controller.
Info
3
No tool connected
1- Tool has been disconnected.
2- If the tool is not physically disconnected, check the tool cable.
Info
4
Span fail.
1- Span value from torque sensor is outside bounds.
2 -Try once again to start the tool with no mechanical constraints. If the
problem occurs again, contact your Desoutter representative for support
Info
5
Offset fail.
1- Offset value from torque sensor is outside bounds.
2- Try once again to start the tool with no mechanical constraints. If the
problem occurs again, contact your Desoutter representative for support.
Info
15
Tool lock on reject
1- The tool is locked forward after a NOK.
2- Unlock the tool in function of the "lock on reject option" selection i.e. by
reversing, loosening or input.
Info
16
Tool lock by OP
1- Tool has been locked by Open Protocol
2- Unlock the tool by sending an Enable tool message via Open Protocol
Info
17
Loosening prohibited
1- Loosening is prohibited
2- The loosening is disabled in the Assembly action
3- The batch count type OK + NOK is used
Info
21
Max retries reached
1- The number of retries max has been reached.
2- The tool is locked.
3- The running Assembly Process has to be aborted.
Info
22
Lock wait socket
1- The tool is locked. Put all sockets back and lift the correct socket(s)
combination.
Info
24
Loos. prohib. XML
1- Loosening is disabled by VWXML protocol
Info
25
Tight. prohib. XML
1- Tightening is prohibited by VWXML protocol
Info
26
Tool maint. alarm n1
1- Tool maintenance tightening counter has been reached
Info
27
Tool maint. alarm n2
1- Tool maintenance tightening counter has been reached
Info
38
Tool logs
1- Unexpected tool software exception
2- Log file has been generated by the tool
3-Contact your Desoutter representative for support
Info
40
Tool over speed
1- Motor speed exceeds 130% of its maximum value.
2- Check tool parameters.
3- Wrong motortune parameters. Contact your Desoutter representative
for support.
Info
42
Tool locked by GeoPos.
1- Tool has been locked by GeoPositioning
2- Unlock the tool by moving the tool in its defined area
Info
43
Tubenut maintenance
1- Tubenut settings need to be reconfigured. Please, use CVI Monitor
and refer to user's guide.
2- Contact your Desoutter representative for procedure
Info
44
GeoTracking/Positioning
learning mode ongoing
GeoTracking/Positioning learning mode
Info
46
Anormal battery current
1- Anormal battery current consumption, check your PSet settings.
2- This error can due to speed settings.
Info
50
Tool detection for pairing
No procedure
Info
51
ePOD connected
ePOD connected
Info
54
Pairing success
No procedure
Info
55
eDOCK already present on
controller
No procedure
Info
56
ePOD disconnected
ePOD disconnected
Info
57
Pairing error
No procedure
Info
58
Tool locked by GeoTrack.
1- Tool has been locked by GeoTracking
2- Unlock the tool by moving the tool in its defined are
Info
59
New tool detected
No procedure
Info
60
Tool synchro ongoing
No procedure
APPENDIX - USER INFO CODES
Info
For information only. No action is required.
Warning
The tool is locked. Tap the message to unlock the tool.
Error
The tool is locked. The issue has to be solved to unlock the tool and clear the error message.
Содержание CVI3 Function
Страница 2: ......
Страница 5: ...Table of contents_02 2017 5...
Страница 27: ...Appendix I O and events_02 2017 27...
Страница 35: ...Appendix User info codes_02 2017 35...
Страница 43: ......
Страница 44: ...www desouttertools com Copyright 2017 More Than Productivity...