Appendix - User info codes_02/2017
- 29 -
Type of
code
Code
no.
Description
Resolution procedure
Info
61
ExBC connection conflict
1- 2 ExBC are configured with the same network settings
2- Verify communication ports and IP addresses
Info
100
Cable id invalid param
1- Invalid tool cable parameter, check that the tool cable is Desoutter
certified
2- Contact your Desoutter representative for support
Info
101
Cable id not detected
1- Tool cable communication error, check that the tool cable is Desoutter
certified
2- Contact your Desoutter representative for support
Info
102
Cable id not certif
1- Tool cable authentification error, check that the tool cable is Desoutter
certified
2- Contact your Desoutter representative for support
Info
199
Console activated
1- The serial console is activated.
2- Warning, this console is dedicated only to debug purposes and should
not be used in production
Info
202
Fieldbus lost
1- Fieldbus connection with PLC is lost.
- no heartbeat is received from PLC
- the cable is broken or disconnected
- the PLC is off line or not powered
2- Check the Fieldbus configuration.
Info
204
Tool not validated
1- Tool locked by I/O.
2- Check the I/O settings: the "Tool validation" must be active to unlock the
tool.
Info
205
Torque settings
1-Invalid Torque setting, torque is greater than tool characteristics
2-Check Pset settings with the current tool characteristics
Info
206
Speed settings
1-Invalid speed setting, speed is greater than tool characteristics
2-Check Pset settings with the tool max. speed.
Info
207
Assembly done
1- Assembly Process is done, the tool is locked
2- Select new Assembly Process to unlock the tool
Info
208
Invalid run reverse param
1-Invalid Run reverse setting, torque or speed are greater than tool
characteristics or reverse strategy is not supported
2-Check Pset settings with the current tool characteristics
3-Reduce max number of turns
Info
209
Pset invalid parameters
1 - Software internal error.
2 - Pset is corrupted. Try to transfer it again to the controller.
3 - If the error persists contact your Desoutter representative for support.
Info
210
Invalid Pset selected
1- The Pset currently selected does not match the selectable one in the
Assembly Process.
Info
211
Invalid trigger conf
1- The tool currently connected to the CVI3 is not equipped with the trigger
required by the tool trigger configuration
2- Adjust your tool trigger configuration to the tool connected or change the
tool according to the expected trigger configuration
Info
215
Current calib. err.
1- Current calibration failed.
2- Try once again.
3- If the problem occurs again, contact your Desoutter representative for
support.
Info
224
IGBT too hot
1- Power electronics too warm.
2- Let the controller cool down.
Info
225
Err. angle
1- Tool communication error.
2- Check tool and cable connections. If the problem occurs again, contact
your Desoutter representative for support.
Info
226
Err. torque
1- Tool communication error. Check tool and cable connections.
2- Try once again, if the problem occurs again, contact your Desoutter
representative for support.
Info
234
Fieldbus mismatch
1-The Fieldbus module declared in configuration is not the same that the
one present in controller (e.g. Profibus declared but a Profinet module in
CVI3).
Info
237
Invalid data
1- The Fieldbus mapping has too many items.
Info
238
Invalid address
1- The device address affected to Fieldbus is invalid.
Info
239
Invalid com settings
1- Fieldbus communication settings are invalid
Info
241
CVINet FIFO alarm
1- The CVINet result FIFO has reached alarm threshold, the CVINet
connection has been lost
2- Check the CVI3 Ethernet cable
3- Check CVI3 Ethernet configuration
4- Check if CVINet is running correctly
Содержание CVI3 Function
Страница 2: ......
Страница 5: ...Table of contents_02 2017 5...
Страница 27: ...Appendix I O and events_02 2017 27...
Страница 35: ...Appendix User info codes_02 2017 35...
Страница 43: ......
Страница 44: ...www desouttertools com Copyright 2017 More Than Productivity...