www.desatech.com
111826-03H
9
Figure 9 - Equipment Shutoff Valve
Equipment
Shutoff
Valve
Open
Closed
Figure 11 - Checking Gas Joints
(Natural Gas Only)
Equipment Shutoff Valve
Gas Meter
INSTALLATION
Continued
3. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas, or using compressed air.
4. Check all joints of gas supply piping system.
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect appliance and equipment
shutoff valve to gas supply. Check recon-
nected fittings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see
Figure 9).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas, or using compressed air.
3. Check all joints from gas meter to equip
-
ment shutoff valve for natural gas or pro-
pane/LP supply to equipment shutoff valve
for propane/LP (see Figures 10 and 11).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 10 - Checking Gas Joints
(Propane/LP Gas Only)
Equipment Shutoff Valve
Propane/LP Tank
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve (see
Figure 9).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of appliance is in
OFF position.
4. Check all joints from equipment shutoff
valve to gas control (see Figures 10 and
11). Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light appliance (see
Operation,
page 10).
Check all other internal joints for leaks.
7. Turn off appliance.
INSTALLING RECEIVER AND
COVER LOG
1. Place receiver into position beside chassis
in fireplace. Receiver should lay flat on
floor of fireplace (see Figure 12).
2. Place receiver cover log over receiver.
This will hide receiver from view (see
Figure 12).
Figure 12 - Receiver and Cover Log
Log Set
Receiver Flat
on Service
Receiver
Cover Log
Antenna
on Top of
Receiver