www.desatech.com
111826-03H
11
8. Short tapping of either button allows
incremental change in flame height.
9. Press OFF button to switch off main gas
and pilot gas.
10. To turn off burners only, press
to
decrease flame height and shut off main
burner. Close equipment shutoff valve
(see Figure 9, page 9).
FUNCTIONS OF
REMOTE CONTROL
battery
• After charged battery has been correctly
installed, remote hand set is ready for
operations.
• Remove battery if remote handset will not
be used more than one year.
Changing Code
The control is radio frequency operated. A
code (chosen from among 4,000 available
codes) is preset for all valves, but can be
changed if required (15 additional codes avail-
able). Change DIP switch position. (DIP switch
is located inside hand held control at top of
battery compartment.) Press receiver's reset
button on bottom of receiver module until you
hear a second (longer) signal. When pressing
button on remote handset in the following
20 sec., receiver learns new code.
Shut Off Procedure
To save battery power; press
to turn main
gas to pilot gas. Press OFF button to shut off
heater including pilot flame. Heater can be
shut off with ON/OFF switch, thus disabling
remote hand set.
OPERATION
Continued
REMOTE OPERATION
Setting Display ( °C/24h and °F/12h)
Press and hold OFF and
until display
changes from °F (and 12 hour clock) to °C
(and 24 hour clock) or vice versa.
Setting Time
• After connecting battery or by simultane
-
ously pressing
and
display will start
to flash. You are in SET mode.
• From SET mode press
to set hour and
to set minute.
• Wait or press OFF to return to manual
mode.
Battery Replacement
Remote handset battery needs to be changed
when LED is dim. Battery life expectancy is
2 to 3 years. If 4 "AA" batteries are used in
receiver, replacement is recommended at the
beginning of heating season. Battery needs
to be changed when acoustic error message
appears during ignition (see
Identifying Error
Signals from Receiver
on page 16).
TO TURN OFF GAS
TO APPLIANCE
Press OFF button on remote control to switch
off main gas and pilot gas.
MANUAL OPERATION
LIGHTING
PROCEDURE
WARNING: Manual lighting
must be performed by a qualified
service person.
The system has a "MANUAL OVERRIDE"
feature that allows you to light with a match.
Lighting with a Match
1. STOP! Read safety information, page 10.
2. Make sure equipment shutoff valve is
fully open.
3. Turn motor knob clockwise
to OFF
position.
4. Wait (5) minutes to clear any gas and then
smell for gas around heater and near floor. If
you smell gas, STOP! follow "B" on page 10.
If you do not smell gas, go to next step.
5. Make sure ON/OFF switch is in "–" (ON)
position.
6. With MAN knob on valve in MAN position,
a metallic core is visible. (see Figure 14,
page 12).
7. Push and hold down metal core fully by
using a non-sharp object such as a pen.
This lets pilot gas flow.