*40
Radio Mode
1-4
3
(0=OFF)
1 = Simplex
2 = Tail Defeat
3 = Half Duplex
4 = Full Duplex
5 = MAP27
*42
Digital VOX Audio Delay
0-1000
0000
ms of audio delay after keying transmitter.
(Prevent syllable loss from telephone party)
*43
COS Ignore after PTT off
(Repeater tail ignore) in VOX
slam-back mode only
0-3000
0420
ms ignore COS after PTT released.
(ms from PTT off until COS recognized to
prevent oscillation between Tx and Rx)
*44
Interconnect Facility Disable
0,1
0
0 = TACT Interconnect facility enabled
1 = TACT Interconnect facility disabled
NOT IMPLEMENTED
*45
Redial Busy
0,1
0
0 = terminate on busy number
1 = redial busy number
NOT IMPLEMENTED
*46
Alarm Dialer
0,1
1
0 = no alarm dialer
1 = alarm dial on alarm input (number(s) must be
programmed – refer to ‘Alarm Input’)
*47
Remote On Off
0,1
0
1 = normal
2 = allow remote control on/off
NOT IMPLEMENTED
*48
Unanswered call indicator
0,1
0
0 = normal
1 = allow caller to leave number
NOT IMPLEMENTED
*49
Aux 1 output relay mode
0-5
1
0 = OFF
1 = on for 2 seconds
(NOT while button pressed)
2 = latch on or off
3 = on for 8 minutes
4 = follow alarm input
5 = on while telephone line 1 is looped
*50
Aux 2 output relay mode
0-5
1
0 = OFF
1 = on for 2 seconds
(NOT while button pressed)
2 = toggle on or off
3 = on for 8 minutes
4 = follow alarm input
5 = on while telephone line 2 is looped
*51
Alternate LEDS
0,1
0
0= normal
1 = alternate LED functions
*52
Error Number
0,1
0
0 = no error number
1 = error numbers
NOT IMPLEMENTED
*53
Emergency Dial Delay
0-60
00
Seconds for emergency dial to occur
NOT IMPLEMENTED
*54
Alarm Message to Air Repeat
Timer
0-65
60
Seconds between alarm message to air
0 = Once to Air only without siren
*55
PRVA allowed
0,1
0
0 = no PRVA
1 = PRVA
NOT IMPLEMENTED
*56
DTMF Rx min on detect
0-255
040
ms of DTMF before detection
*57
DTMF Rx max off detect
0-255
040
ms gap in DTMF before absence
*58
COM baud rate
0-5
3
0 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
*59
COM1 baud rate
0-5
3
Ditto
*60
COM2 baud rate
0-5
3
Ditto