________________________________________________________________________________________________
__________________________________________________________________________________________________________
Operator Manual for TACT TA-4800 in NSW National Parks & Wildlife Service User Mode G/00123B Issue 1 Page 8
FACTORY OPTIONS
ALARM INPUT
Alarm systems such as a security alarm, a door open alarm or mains failure alarm can be connected to the
TACT alarm input (Pins 4 & 5 of the
‘ALARM’
connector). Should the alarm be triggered, TACT can:
i.
Send an "
Alarm activated
" message to air (see
‘System Configuration’
).
ii.
Dial up to four telephone numbers and send an "
Alarm activated
" message to line (see below).
iii.
Initiate a Page call.
iv.
Activate auxiliary output relay one to perform an external function.
ALARM DIALER
TACT can perform the function of an alarm dialer. Up to 4 different telephone numbers can be dialed in
succession where the "
Alarm activated
" message is played to each number for thirty seconds. When you
receive an alarm call, you can press # to acknowledge the alarm and stop TACT from dialing any further for
that alarm.
To Enter the First Alarm Dial Number
1.
Press * 81 x nnnnnnnnnn #, where x is the number of dial attempts and nnnnnnnnnn is the number to be dialed.
To Enter the Second Alarm Dial Number
1.
Press * 82 x nnnnnnnnnn #, where x is the number of dial attempts and nnnnnnnnnn is the number to be dialed.
To Enter the Third Alarm Dial Number
1.
Press * 83 x nnnnnnnnnn #, where x is the number of dial attempts and nnnnnnnnnn is the number to be dialed.
To Enter the Fourth Alarm Dial Number
1.
Press * 84 x nnnnnnnnnn #, where x is the number of dial attempts and nnnnnnnnnn is the number to be dialed.
To Erase a Number
1.
Enter a single ‘0’ in place of x nnnnnnnnnn as detailed just above.
AUXILIARY OUTPUT RELAYS (OPTIONAL)
The Auxiliary Output Relays can be connected to most switchable systems. This provides for the control of
sirens, security systems, power gates, electric door strikes and more. The relay(s) can remain latched,
automatically reset,
or automatically be activated by certain events.
See page 17 for connection details.
To Operate the Relay One
1.
Press * 07 1 #. Listen for "
Relay one operated
".
To Interrogate the Relay One State
1.
Press * 07 #. Listen for "
Relay one operated
" or "
Relay one idle
".
To Reset the Relay One
1.
Press * 07 0 #. Listen for "
Relay one idle
".
To Operate the Relay Two
1.
Press * 08 1 #. Listen for "
Relay two operated
".
To Interrogate the Relay Two State
1.
Press * 08 #. Listen for "
Relay two operated
" or "
Relay two idle
".
To Reset the Relay Two
1.
Press * 08 0 #. Listen for "
Relay two idle
".