4.3. SETTINGS / ADMINISTRATION MENU
You can change settings of your motorized cylinder and perform administrative activities via this menu. Before using your
smart cylinder, “number of turns” and “locking way” settings should be adjusted properly. Otherwise, it would damage the
device’s mechanical structure.
The menu items and order is as follows:
LR
DL
CL
TC
MW
UC
BU
RF
Display
Enrolling new fingerprints
Deleting enrolled fingerprints one by one
Deleting all fingerprints (Reseting fingerprint reader)
Adjusting motorized cylinder according to lock’s number of rotation to lock/unlock
Adjusting direction of locking according to door’s opening way
Showing total number of enrolled fingerprints in the device’s memory
Enabling or disabling buzzer sound (Warning tones are always active)
Enabling or disabling automatic locking mode which locks cylinder 1 minute after it is unlocked
Function
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
MA
Enabling or disabling delayed locking which locks 5 s. after locking button on the cylinder is pressed.
1
2
ML
MD
MC
HT
Shifting the motorized cylinder to enrolling mode to learn new controllers
Deleting all controllers enrolled to cylinder except master controller.
Reporting number of controllers enrolled to motorized cylinder via buzzer sound
Adjusting latch retraction period.
2
2
2
1
1
1
1
2
*
Not available in some versions of fingerprint reader.