4.  A “PASS” test result is indicated by illumination 

of the green LED.  A “FAIL LOW” test result is 

indicated by illumination of the red LED.  A “FAIL 

HIGH” test result is indicated by illumination of the 

yellow LED. 

 

If your ESD test fails, check your footwear and 

ensure that it is being worn correctly and/or needs 

to be replaced.

NOTE 1: The Combo Tester may briefly display “FAIL 

HIGH” once the test button is released at the conclusion 

of a test.  Residual voltage in the circuit’s capacitors 

causes the test to continue for a split second after the 

button is released. 
NOTE 2: Failures may be caused by dry skin or minimal 

sweat layer.  Footwear test results can be improved 

by taking a short walk to build a sweat layer for better 

conductivity.
5.  Repeat steps 2-4 for the second foot.

Maintenance

The Combo Tester requires little maintenance.  There 

are no user serviceable parts.  If your meter requires 

service beyond cleaning the test switch or foot plate, 

please contact the factory.
Use a minimum of 80% isopropyl alcohol to clean the 

test switch.  Other cleaners are susceptible to leaving 

residue.

BATTERY REPLACMENT

The low battery indicator flashes briefly every time 

the unit is used.  Replace the battery once the 

indicator becomes constant during testing.

  

Open 

the compartment located on the back of the tester to 

replace the battery.  The tester uses one 9V alkaline 

battery.

Calibration

The Desco Combo Tester is calibrated to NIST 

traceable standards.  There are no user adjustments 

necessary.  We recommend that calibration be 

performed annually using the Desco 

07010

 Calibration 

Unit.  It is a convenient product which allows the 

customer to perform NIST traceable calibration on 

single-wire personnel testers.  The 

07010

 is designed 

to be used on the shop floor at the workstation, virtually 

eliminating downtime, verifying that the tester is 

operating within tolerances.
View technical bulletin 

TB-2039

 for more information on 

the 

07010

 Calibration Unit and instructions to calibrate 

the Combo Tester.

Figure 15.  Replacing the battery

Figure 16.  Desco 

07010

 Calibration Unit

Содержание 19280

Страница 1: ...fillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for ...

Страница 2: ...ton Head Screws 1 4 20 x 3 4 1 Allen Wrench 5 32 1 Flat Head Screw 8 32 x 5 8 1 Knurled Nut 8 32 1 Black Cap 1 Poster 1 Certificate of Calibration 19283 COMBO TESTER WITH STAINLESS STEEL FOOT PLATE 1 Combo Tester 1 Foot Plate Cord 5 inches 1 9V Battery 1 Stainless Steel Foot Plate 1 Foot Plate Cord 6 feet 1 Certificate of Calibration Figure 2 Desco 19282 Combo Tester with Stand and Foot Plate Figu...

Страница 3: ...l foot plate 19283 98273 D Rocker Switch Toggle to the left when performing a footwear test Toggle to the right when performing a wrist strap test E Single Wire Wrist Strap Jack Insert your single wire wrist cord here to test your wrist strap F Test Switch Push down and hold your finger here to perform a test G Low Battery LED Illuminates when the battery power is low and needs to be replaced 9825...

Страница 4: ... plate using the 3 included button head screws and allen wrench Figure 8 Combo Tester keyhole slots 4 Mount the Combo Tester onto the screws and pull it down to secure it into place 5 Set the Stainless Steel Foot Plate below the tester if applicable 6 Insert the 6 long foot plate cord s banana plug into the Combo Tester s foot plate jack Figure 9 Inserting the foot plate cord s banana jack into th...

Страница 5: ... and or needs to be replaced NOTE 1 The Combo Tester may briefly display FAIL HIGH once the test button is released at the conclusion of a test Residual voltage in the circuit s capacitors causes the test to continue for a split second after the button is released NOTE 2 Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion such as...

Страница 6: ... There are no user serviceable parts If your meter requires service beyond cleaning the test switch or foot plate please contact the factory Use a minimum of 80 isopropyl alcohol to clean the test switch Other cleaners are susceptible to leaving residue BATTERY REPLACMENT The low battery indicator flashes briefly every time the unit is used Replace the battery once the indicator becomes constant d...

Страница 7: ...Desco Terms and Conditions Specifications COMBO TESTER Power Supply 9V Alkaline Battery or optional AC power adapter Operating Temperature 32 F to 104 F 0 to 40 C Wrist Strap Test Limit 750 kilohms to 10 megohms Footwear Test Limit 750 kilohms to 100 megohms Test Accuracy 20 Test Voltage 4 VDC Dimensions 3 3 x 5 6 x 1 5 Weight 0 5 lbs STAND AND FOOT PLATE Stand Height 36 Foot Plate Dimensions 18 x...

Отзывы: