OBSERVED PROBLEM

Burner does not light after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

White powder residue forming within burner
box or on adjacent walls or furniture

REMEDY

1. Clean burner (see Cleaning and Main-

tenance, page 21) or replace burner orifice

2. Contact local propane gas company
3. Replace burner orifice
4. Reconnect leads (see Wiring Diagram,

page 20)

5. Replace battery in transmitter and

receiver

1. Contact local propane gas company
2. Clean burner (see Cleaning and Main-

tenance, page 21) or replace burner orifice

1. Clean burner (see Cleaning and

Maintenance, page 21) or replace burner
orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, page 21)

2. Replace gas control
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane gas company

3. Observe minimum installation clear-

ances (see pages 8 through 10)

4. Clean burner (see Cleaning and Mainte-

nance, page 21) or replace burner orifice

1. Turn heater off when using furniture pol-

ish, wax, cleaners, or similar products.

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im-

properly connected

5. Burners will not come on in remote po-

sition

1. Manifold pressure is too low
2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue.

Содержание VYGF33PR

Страница 1: ...n and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damag...

Страница 2: ...ebris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running firepl...

Страница 3: ...UNPACKING 1 With utility knife cut the carton all the way around above the staples on the bottom tray Lift the carton off the heater Remove packing Note The hood is located in the packing on the righ...

Страница 4: ...ou classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dowsmayprovideenoughfreshairforcom bustion and ventilation However in build...

Страница 5: ...______ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual...

Страница 6: ...ilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thes...

Страница 7: ...ssem bling and attaching brass trim to fireplace 1 Remove packaging from three pieces of brass trim 2 Locate four brass screws two adjust ing plates with set screws and two shims in the hardware packe...

Страница 8: ...net mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical outlet at fire...

Страница 9: ...e 16 page 10 Follow the instructions below to install the fireplace in this manner Figure 15 Attaching Fireplace to Wall Studs Nailing Flanges Nails or Wood Screws 39 3 8 27 7 8 55 5 8 35 1 2 Figure 1...

Страница 10: ...urface above the Firebox Hood Mantel Shelf 13 16 19 21 2 1 2 6 8 10 Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf These minimum clearances replace any...

Страница 11: ...optional A G A design cer tifiedmanualshutoffvalvefromyourdealer See Accessories pages 22 and 23 Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within re...

Страница 12: ...fireplace and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace gas regulator 2 Cap off open end of gas pipe where manual shutoff...

Страница 13: ...only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS Itisveryimportanttoinstallthelogsexactly as instucted Do not modify logs Only use log...

Страница 14: ...loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the remote selector switch is in the ON position after the pilot...

Страница 15: ...to pilot GHRCT Operation 2 Select the MANUAL or AUTO but ton on the hand held remote control unit GHRCT only see Figure 28 In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on t...

Страница 16: ...e blower will start when the thermostat sensesasufficientincreaseinfireboxtem perature Note Your gas logs and thermostat blower will not turn on and off at the same time The fireplace may run for seve...

Страница 17: ...5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor c...

Страница 18: ...ion 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line che...

Страница 19: ...Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace prod...

Страница 20: ...ified heat propane LP gas supply may be low When gas quality is bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas q...

Страница 21: ...areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleanin...

Страница 22: ...ted on the back page of this manual QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQ QQQ QQQ QQQQQQQQQQ QQQQQQQQQQ QQQQQQQQQQ CABINET MANTEL GM100F Series Walnut Finished GM101U Seri...

Страница 23: ...selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas log heater t...

Страница 24: ...UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL VYGF33PR 17 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 4 14 13 25 15 16 21 11 10 19 20 19 2...

Страница 25: ...ce Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1 14 098265 02...

Страница 26: ...26 104353 UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN FIREPLACE VYGF33PR 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Страница 27: ...ght Front Side 1 4 102759 02CK Left Front Side 1 5 098304 01 Phillips Pan Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder...

Страница 28: ...uch other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCL...

Отзывы: