background image

9

104353

OWNER’S MANUAL

INSTALLATION

Continued

Figure 12 - Inserting Fireplace Into Cabinet
Mantel

,,,,,

,,,,,

QQQQQ

QQQQQ

¢¢¢¢¢

¢¢¢¢¢

,,,

,,,

,,,

,,,

,,,

QQQ

QQQ

QQQ

QQQ

QQQ

¢¢¢

¢¢¢

¢¢¢

¢¢¢

¢¢¢

Figure 11 - Location of Nailing Flanges

Nailing
Flanges

Continued

Gas Supply, page 11.

10. If blower is installed, route blower elec-

trical cord through access holes in ei-
ther side of fireplace. 

Note:

 Bushing

may be moved if necessary. Plug elec-
trical cord into electrical outlet.

11. Carefully insert fireplace into cabinet

mantel. Be careful not to scratch or
damage hearth base, cabinet mantel, or
any laminate trim on hearth base. Re-
move protective material from top of
hearth base and from front of fireplace
(if any). 

Note:

 You can secure fireplace

to hearth or floor. Open lower louver.
Locate screw holes in bottom of base.
Tighten wood screws through these
holes and into hearth or floor.

12. Check all gas connections for leaks. See

Checking Gas Connections, page 12.

Actual

Framing

Height

32 

3

/

8

"

33"

Front Width

34 

5

/

16

"

35 

1

/

2

"

Depth

16 

11

/

16

"

17 

3

/

4

"

35 1/2"

17 3/4"

33"

Figure 13 - Rough Opening for Installing
in Wall

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. If installing a mantel above the
fireplace, you must follow the clearances
shown in Figure 16,

 

page 10. Follow the

instructions below to install the fireplace in
this manner.

Figure 15 - Attaching Fireplace to Wall
Studs

Nailing Flanges

Nails or
Wood
Screws

39 3/8"

27 7/8"

55 5/8"  

35 1/2"

Figure 14 - Rough Opening for Installing
in Corner

1.

Frame in rough opening. Use dimen-
sions shown in Figure 13 for the rough
opening.

If installing in a corner, use dimensions
shown in Figure 14 for the rough open-
ing. The height is 33" which is the same
as the wall opening above.

2.

If using blower, install and properly
ground GA3555, three-prong 120 volt
electrical outlet, in fireplace. Follow
instructions included in kit (see Acces-
sories, 
page 22).

3.

Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping. See In-
stalling Gas Piping to Fireplace Loca-
tion,
 page 10.

4.

Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.

5.

Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Sup-
ply,
 page 11.

6.

Plug electrical cord into electrical out-
let installed in step 2.

7.

Carefully insert fireplace into rough
opening.

8.

Attach fireplace to wall studs using
nails or wood screws through holes in

nailing flange (see Figure 15).

9.

Check all gas connections for leaks. See
Checking Gas Connections, page 12.

10. Install brass trim after final finishing

and/or painting of wall (see Figure 7,
page 7).

Содержание VYGF33PR

Страница 1: ...n and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damag...

Страница 2: ...ebris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running firepl...

Страница 3: ...UNPACKING 1 With utility knife cut the carton all the way around above the staples on the bottom tray Lift the carton off the heater Remove packing Note The hood is located in the packing on the righ...

Страница 4: ...ou classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dowsmayprovideenoughfreshairforcom bustion and ventilation However in build...

Страница 5: ...______ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual...

Страница 6: ...ilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thes...

Страница 7: ...ssem bling and attaching brass trim to fireplace 1 Remove packaging from three pieces of brass trim 2 Locate four brass screws two adjust ing plates with set screws and two shims in the hardware packe...

Страница 8: ...net mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical outlet at fire...

Страница 9: ...e 16 page 10 Follow the instructions below to install the fireplace in this manner Figure 15 Attaching Fireplace to Wall Studs Nailing Flanges Nails or Wood Screws 39 3 8 27 7 8 55 5 8 35 1 2 Figure 1...

Страница 10: ...urface above the Firebox Hood Mantel Shelf 13 16 19 21 2 1 2 6 8 10 Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf These minimum clearances replace any...

Страница 11: ...optional A G A design cer tifiedmanualshutoffvalvefromyourdealer See Accessories pages 22 and 23 Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within re...

Страница 12: ...fireplace and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace gas regulator 2 Cap off open end of gas pipe where manual shutoff...

Страница 13: ...only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS Itisveryimportanttoinstallthelogsexactly as instucted Do not modify logs Only use log...

Страница 14: ...loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the remote selector switch is in the ON position after the pilot...

Страница 15: ...to pilot GHRCT Operation 2 Select the MANUAL or AUTO but ton on the hand held remote control unit GHRCT only see Figure 28 In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on t...

Страница 16: ...e blower will start when the thermostat sensesasufficientincreaseinfireboxtem perature Note Your gas logs and thermostat blower will not turn on and off at the same time The fireplace may run for seve...

Страница 17: ...5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor c...

Страница 18: ...ion 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line che...

Страница 19: ...Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace prod...

Страница 20: ...ified heat propane LP gas supply may be low When gas quality is bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas q...

Страница 21: ...areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleanin...

Страница 22: ...ted on the back page of this manual QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQ QQQ QQQ QQQQQQQQQQ QQQQQQQQQQ QQQQQQQQQQ CABINET MANTEL GM100F Series Walnut Finished GM101U Seri...

Страница 23: ...selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas log heater t...

Страница 24: ...UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL VYGF33PR 17 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 4 14 13 25 15 16 21 11 10 19 20 19 2...

Страница 25: ...ce Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1 14 098265 02...

Страница 26: ...26 104353 UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN FIREPLACE VYGF33PR 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Страница 27: ...ght Front Side 1 4 102759 02CK Left Front Side 1 5 098304 01 Phillips Pan Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder...

Страница 28: ...uch other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCL...

Отзывы: