www.desatech.com
113109-01C
18
OpTIONAL WIRELESS HAND-HELD
REMOTE CONTROL ACCESSORIES
(HRC100 and HRC200)
Installing Remote Receiver Unit
1. Disconnect switch wires from the control
valve.
2. Remove screws attaching switch plate.
3. Remove switch plate (see Figure 33). Discard
after removing.
4. Install remote receiver unit onto gas log heater
base using mounting clips.
5. Push clips firmly into place (see Figure 34).
6. Connect wires as shown in Figure 35.
Figure 33 - Switch Plate and Wiring
Harness
Figure 34 - Installing Remote Receiver
Valve
White Wire
From Receiver
Screw
Switch Plate
Wires
Remote
Switch
Bracket
Ignitor
Remote Receiver
Mounting
Clips
Figure 35 - Connecting Wires
Red Wire From
Receiver
FpvF Models Only
1. Place one-piece log set on grate to fit as illus-
trated in Figure 31. Make sure middle section
at bottom of log set is seated into “U”-shaped
cutout in center of chassis (see Figure 31).
IMPORTANT:
Make sure log does not cover
any burner ports (see Figure 32).
2. Install fireplace screen by slipping notches
of fireplace screen over screws on front of
fireplace (see Figure 30, page 17).
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is in place before
running fireplace.
INSTALLATION
Continued
O
F
F
P
ILO
T
O
N
H
I
L
O
Chassis
Burner
One Piece
Log Set
Middle
Section at
Bottom of
Log Set
"U" Shaped
Cutout In
Chassis
Figure 31 - Installing One Piece Log Set
Figure 32 - Installing One Piece Log Set,
Top View
One Piece
Log Set
Burner Ports