www.desatech.com
113109-01C
TROUbLEShOOTING
Continued
pOSSIBLE CAUSE
1. Control knob not fully pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
5. Thermocouple connection
loose at control valve
6. Thermocouple damaged
7. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orifice(s) clogged
3. Thermopile leads disconnected
or improperly connected
4. Burner will not come on in
remote position
1. Manifold pressure is too low
2. Burner orifice(s) clogged
1. Burner orifice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing
processes and logs curing
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Fully open equipment shutoff
valve
4. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance
,
page 24) or replace ODS/pilot
assembly
5. Hand tighten until snug, then
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see
Cleaning
and Maintenance
, page 24) or
replace burner orifice(s)
3. Reconnect leads (see
Wiring
Diagram,
page 29)
4. Replace battery in transmitter
and receiver
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see
Cleaning
and Maintenance
, page 24) or
replace burner orifice(s)
1. Clean burner (see
Cleaning
and Maintenance
, page 24)
or replace burner orifice(s)
2. Replace damaged burner
3. Replace gas regulator
1. Check burner for dirt and
debris. If found, clean burner
(see
Cleaning and Mainte-
nance
, page 24)
2. Replace gas control
3. Problem will stop after a few
hours of operation
OBSERvED pROBLEM
ODS/pilot lights but flame
goes out when control knob is
released
Burner does not light after
ODS/pilot is lit
Delayed ignition of one or both
burners
Burner backfiring during com-
bustion
Slight smoke or odor during
initial operation