www.desatech.com
121082-01G
15
Note: If adding the G8007 series brick liner
accessory, install it now. Follow instructions
in G8007 accessory kit.
CAUTION: Do not pick up
log base assembly by burner.
This could damage burner. Only
handle base by grates.
3. Route gas line (provided by installer)
from equipment shutoff valve to fireplace.
Route flexible gas supply line through one
of the access holes.
NOTICE: Most building codes
do not permit concealed gas
connections. A flexible gas line
is provided to allow accessibility
from the fireplace (see Figure 17).
The flexible gas supply line con
-
nection to the equipment shutoff
valve should be accessible.
4. Attach flexible gas line to gas supply (see
Figure 17). Check tightness of flexible gas
line attached to gas regulator of fireplace
(see Figure 17).
5. Check all gas connections for leaks. See
Checking Gas Connections,
page 16.
6. Replace log base assembly back into
fireplace. Feed flexible gas line into fire
-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat
-
tach log base assembly to fireplace with
screws removed in step 2.
INSTaLLaTION
Continued
Figure 16 - Removing Log Base
Assembly From Fireplace
Figure 17 - Attaching Flexible Gas Lines
Together
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer
Propane/LP
To External
Regulator
Natural Gas
To Gas Meter
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment
trap in supply line as shown in Figure 15,
page 14. Locate sediment trap where it is
within reach for cleaning. Install in piping
system between fuel supply and fireplace.
Locate sediment trap where trapped matter
is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them
from going into fireplace gas controls. If sedi
-
ment trap is not installed or is installed wrong,
fireplace may not run properly.
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Remove fireplace screen. Remove one
screw that holds fireplace screen in place
for shipping. This screw is located near
top left side of screen. Discard screw.
Lift fireplace screen up and pull out to
remove.
2. Remove screws that attach log base
assembly to fireplace (see Figure 16).
Carefully lift up log base assembly and
remove from fireplace (see Figure 16).