background image

17

www.desatech.com

117437-01

OPERATING FIREPLACE

Electronic Ignition System

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions

exactly, a fi re or explosion may result causing prop-
erty, damage, personal injury or loss of life.

A.  This appliance is equipped with an ignition device which
 

automatically lights the pilot. Do not try to light the pilot

 by 

hand.

B.  BEFORE LIGHTING smell all around the appliance area
 

for gas. Be sure to smell next to the fl oorbecause some gas

 

is heavier than air and will settle on the fl oor.

 

WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do not touch any electric switch; do not use any phone

  

in 

your 

building.

 

•  Immediately call your gas supplier from a neighbor’s

 

  Phone. Follow the gas supplier’s instructions.

 • 

If you cannot reach your gas supplier, call the fi re department.

C.  Do not use this appliance if any part has been under
 

water. Immediately call a qualifi ed service techni-

 

cian to inspect the appliance and to replace any part

 

of the control system and any gas control which has

 been 

under 

water.

LIGHTING

INSTRUCTIONS

1.  STOP! Read the safety information above.
2.  Turn off all electrical power to the fi replace.
3.  Turn wall switch to the OFF position.
4. Open 

lower 

louver 

panel.

5.  Turn equipment shutoff valve clockwise           to the OFF
 

position (see Figure 34). Do not force.

6. Wait 

fi ve (5) minutes to clear out any gas. Then smell for.

 

gas, including near the fl oor. If you smell gas, STOP! Fol-

 

low “B” in the safety information above. If you don’t smell

 

gas go to the next step.

7.  Turn equipment shutoff valve counterclockwise             to.
 

the ON position. Do not force.

8. Close 

lower 

louver 

panel.

9.  Turn on all electric power to the fi replace.
10.  Turn the wall switch to the ON position.
11.  Visually locate the pilot. The ignitor should begin to spark and

the main burner should ignite once fl ame appears at pilot.
•  If lighting the appliance for the fi rst time each season, it

 

  may take several attemps before the supply gas can reach

 

  the pilot and main burner. 
•  If the appliance will not stay lit after several attempts,

 

  follow the instructions 

To Turn Off Gas To Appliance

, be-

 

  low, and call your service technician or gas supplier.

Equipment Shutoff Valve

OFF

ON

Adjustment
Screw

Figure 34 - Turning Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

TO APPLIANCE

1.  Turn off the wall switch.

2.  Turn off all electric power to the appliance if service is to
 be 

performed.

3.  Open lower louver panel.

4.  Turn equipment shutoff valve clockwise        to OFF.
 

Do not force.

5. Close 

lower 

louver 

panel.

OPERATING FIREPLACE - Electronic Ignition System

For Your Safety Read Before Lighting
Lighting Instructions
To Turn Off Gas To Appliance

Pilot Burner

Ignitor

Sensor Rod

Figure 35 - Pilot

OPTIONAL WIRELESS

REMOTE OPERATION

Note:

 The WRC receiver and hand-held remote control kit

must be purchased separately (

see Accessories,

 page 33). Follow

installation instructions included with the remote control.

1.  Turn equipment shutoff valve to ON position. You can now
 

turn the burner on and off with the hand-held remote unit.

 

IMPORTANT:

 Be sure to press the ON/OFF buttons on the

 

hand-held remote control unit for up to 3 seconds to assure

 proper 

operation.

2.  Press the ON/OFF button to turn the burner on and off.

NOTICE: During initial operation of a new heater, the
burning of residues from the manufacturing process
of the fi rebox and logs will produce a paper-burning
smell and orange fl ames. Open a window for the fi rst 
few hours of operation to adequately vent this smell.

Optional Wireless Remote Operation

Содержание (V) CB36(N

Страница 1: ...aftermarket permanently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance...

Страница 2: ......

Страница 3: ...carbon monoxide poisoning resemble the u with headaches dizziness or nausea If you have these signs the replace may not have been installed properly Get fresh air at once Have replace inspected and se...

Страница 4: ...o not use any solid fuels wood coal paper cardboard etc in this replace Use only the gas type indicated on the nameplate 14 This appliance when installed must be electrically grounded in accordance wi...

Страница 5: ...gure 2 shows some common locations Be aware of all restrictions and precautions before deciding the exact location for your replace and termination cap When deciding the location of your replace follo...

Страница 6: ...remove the four corner posts Discard the bottom tray once the unit is moved into position Note To prvent damage to ceramic logs and glass panels you may want to remove them before positioning and fram...

Страница 7: ...NT 14 3 4 375 mm TO NAILING FLANGES 5 8 16 mm 36 914 mm FACE DIM 36 1 4 921 mm FACE DIM 15 3 8 390 mm 35 3 4 908 mm 1 1 2 38 mm 6 152 mm 37 940 mm TO NAILING FLANGE 4 1 2 114 mm ELECTRICAL INLET 8 203...

Страница 8: ...fuel burning apppliance NOTICE Failure to follow these instructions will void the warranty INSTALLATION PRECAUTIONS Wear gloves and safety glasses for protection Use extreme caution when using ladder...

Страница 9: ...12 7 5 2 27 Over 20 12 to 21 12 8 0 2 44 Vent terminations must be located in accordance with height and proximity rules of NFPA No 54 or CAN CSA B149 These rules apply to vents at 12 in diameter or l...

Страница 10: ...junctionboxmountingtab 3 Slide the junction box up until the screw mounting tab is lined up to the notch in the outer cabinet 4 Swing the junction box out and slip the retaining ange out through the s...

Страница 11: ...OPTIONAL WIRELESS HAND HELD REMOTE CONTROL MODEL HRC100 Installing Remote Receiver 1 Open bottom louver and locate the switch bracket on the right 2 Locate the battery clip mounted on the back of the...

Страница 12: ...External Regulator Vent Pointing Down Figure 22 External Regulator with Vent Pointing Down Pro pane LP Only Figure 20 Connecting WRC Remote Control Electronic Fireplace Receptacle Remote Control Rece...

Страница 13: ...PT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from replace see Figure 23 IMPORTANT Install main gas valve equipment shutoff valve in an accessible lcation The main...

Страница 14: ...ment shutoff valve see Figure 25 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LPgas replace or opening main gas valve located on or near gas meter for n...

Страница 15: ...ked or broken Removing Replacing Glass Door If replacement of glass is necessary the entire assembly glass and frame must be replaced If glass is broken wear gloves and tape the remaining fragments on...

Страница 16: ...sitioned against the rear panel 2 Position the holes on the bottom of the rear log over the pins on the base log Figure 31 3 Position the top left log and top right log onto the rear log and base log...

Страница 17: ...e if service is to be performed 4 Push in gas control knob slightly and turn clockwise to OFF 5 Close lower louver panel Shutting Off Berners Only pilot stays lit You may shut off the burners and keep...

Страница 18: ...tric power to the replace 10 Turn the wall switch to the ON position 11 Visually locate the pilot The ignitor should begin to spark and the main burner should ignite once ame appears at pilot If light...

Страница 19: ...nnect the appliance gas controls to a 120 VAC power source Damage or injury may occur Light the replace as instructed in Lighting Instructions on page16 IfusingaHRCremotewithawallswitchsettheremote se...

Страница 20: ...n relation to the sens ing devices should be as shown in Figures 38 and 39 respectively The pilot ame may need adjustment in order for the thermocou ple thermopile and or the ignition system to sense...

Страница 21: ...roken carefully remove glass door see Remov ing Replaceing Glass Door page 14 Vacuum all glass pieces with a shop vac WARNING Turn off replace and let cool before cleaning CAUTION Do not vacumm if pie...

Страница 22: ...valve not fully open 4 Pilot ame not touching thermocouple which alows thermocouple to cool causing pilot to go out This prob lem could be caused by one or more of the following A Low gas pressure B D...

Страница 23: ...l expanding while heating or con tracting while cooling 1 Batteryisnotinstalledorbatteryispower is low 1 Clean burner see Cleaning and Mainte nance page 20 or replace burner ori ce 2 Contact local pro...

Страница 24: ...2 Check local propane LP or natural gas company 3 Clean pilot see Cleaning and Mainte nance page 20 4 Locate and correct all vent conditions seeCheckingforProperVenting page8 5 Clean burner tube and...

Страница 25: ...off valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call for quali ed service and repair 3 Remove debris an...

Страница 26: ...few hours of operation 1 Locate and correct all leaks see Check ing Gas Connections page 13 2 Replace gas conrol valve 1 Adjust the log set that the ame does not excessively impinge on log surfaces 2...

Страница 27: ...contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart ment at 1 866 672 6040 Wh...

Страница 28: ...ARTS BREAKDOWN Models V CB36N V CB36P V CB36NE V CB36PE ILLUSTRATED PARTS BREAKDOWN FIREPLACE ASSEMBLY FOR MODELS V CB36N V CB36P V CB36NE V CB36PE 19 1 2 12 14 12 1 1 16 3 24 8 10 11 17 20 1 4 1 3 2...

Страница 29: ...Deflector 1 8 114875 02 114875 02 Fireplace Surround 1 9 117450 01 117450 01 Wire Harness Assembly 1 10 117451 01 117451 01 Fireplace Top 1 11 117452 01 117452 01 Fireplace Top Insulation 1 12 117445...

Страница 30: ...29 www desatech com 117437 01 ILLUSTRATED PARTS BREAKDOWN Models V CB36N V CB36P ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V CB36N V CB36P 1 2 4 19 8 17 10 9 18 11 5 6 16 12 13 15 14 3 7...

Страница 31: ...14399 Fitting Brass Elbow 3 8 MPT x 3 8 Comp Tube 1 10 14396 14396 Fitting Brass Straight 3 8 MPT x 3 8 Comp Tube 1 11 14512 Gas Control Valve Millivolt Natural Gas 1 11 14513 Gas Control Valve Milliv...

Страница 32: ...m 117437 01 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V CB36NE V CB36PE ILLUSTRATED PARTS BREAKDOWN Models V CB36NE V CB36PE 7 8 10 29 15 27 17 16 28 14 11 12 25 18 19 22 21 9 13 1 2 3 26...

Страница 33: ...as Control Valve Millivolt Natural Gas 1 14 14570 Gas Control Valve Millivolt Propane LP Gas 1 15 14500 14500 Fitting 3 8 MPT x 1 2 Flare 1 16 14399 14399 Fitting Brass Elbow 3 8 MPT x 3 8 Comp Tube 1...

Страница 34: ...Gas Conversion Kit Millivolt Models PCBE 36C Propane LP Gas Conversion Kit Electronic Models NCBE 36C Natural Gas Conversion Kit Electronic Models NOTE All accessories may not be available for all rep...

Страница 35: ...10 000 to 25 000 25 000 to 50 000 50 000 to 100 000 100 000 to 250 000 Over 250 000 5 What is your primary source of heat Propane LP Gas Fuel Oil Wood Natural Gas Electric Other 6 How was the product...

Страница 36: ...TAPE TAPE Postage Required 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004...

Страница 37: ...36 www desatech com 117437 01 NOTES...

Страница 38: ...37 www desatech com 117437 01 NOTES...

Страница 39: ......

Страница 40: ...o repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY...

Отзывы: