www.desatech.com
111604-01E
17
Pressure Testing Fireplace Gas
Connections
1.
Open equipment shutoff valve (see Figure 23,
page 16).
2.
Open main gas valve located on or near gas
meter for natural gas or open propane/LP sup-
ply tank valve.
3.
Make sure control knob of fireplace is in the
OFF position.
4.
Check all joints from equipment shutoff valve
to gas control valve (see Figures 24 or 25, page
16). Apply noncorrosive leak detection fluid
to all joints. Bubbles forming show a leak.
5.
Correct all leaks at once.
6.
Light fireplace (see Operating Fireplace,
pages 19 through 21.) Check all other inter-
nal joints for leaks.
7.
Turn off fireplace (see To Turn Off Gas to
Appliance, page 20).
INSTALLING LOGS
CAUTION: Do not remove
the data plates attached to the
heater base assembly. The data
plates contain important war-
ranty and safety information.
WARNING: Failure to posi-
tion the parts in accordance with
these diagrams or failure to use
only parts specifically approved
with this heater may result in prop-
erty damage or personal injury.
WARNING: After installation
and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to High, check
to see if flame contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact-
ing logs will create soot.
INSTALLATION
Continued
It is very important to install the logs exactly as
instructed. Do not modify logs. Only use logs sup-
plied with fireplace.
1.
Place pins in rear log (log 1) into holes on
rear of base grate as shown in Figure 26.
2.
Place middle log (log 2) between front and
rear of burner. The left side will rest on the
left tab and the right will straddle the burner
as shown in Figure 26.
3.
Place front log (log 3) onto grate fingers at
front of base grate (see Figure 27). Make sure
log seats well into grate.
Figure 26 - Installing Logs 1 and 2
O
F
F
P
IL
OT
O
N
Log 2
Log 1
Figure 27 - Installing Log 3
O
F
F
P
IL
OT
O
N
Log 3