manualshive.com logo in svg
background image

                                                                                                        -2 -                                           

For more information, visit www.desatech.com

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INTRODUCTION 

 

Models GW30B/GW30PB series are gravity direct vent wall 
furnace inserts with a sealed combustion chamber that uses 
millivolt gas control valve and millivolt ignition system.   
 
The system requires a unique termination that includes 
transition pipes.  The flex pipe must be installed only in 
masonry or listed factory built chimney. 
If you are uncertain as to what gas your unit is equipped for, 
please check the rating plate located in the interior of the 
appliance opening or consult your local distributor of DESA 
products. 
 
BEFORE BEGINNING THE INSTALLATION OF THE 
FIREPLACE, READ THESE INSTRUCTIONS THROUGH, 
COMPLETELY. 

♦ 

This DESA fireplace and its components are safe 
when installed according to this installation manual. 
Unless you use DESA components, which has been 
designed and tested for this appliance, you may cause 
a fire hazard.

 

♦ 

The DESA warranty will be voided by and DESA 
disclaims any responsibility for the following actions:

 

a) Modification of the fireplace, components, doors, blower, 
fans, air inlet system and damper control.  
b) Use of any component part not manufactured or approved 
by DESA in combination with a DESA fireplace system. 

 

When installed on site in a Manufactured Home (mobile 

home) installation must conform with the Manufactured Home 

Construction and Safety Standard, Title 24 CFR, Part 3280 or 

when such a standard is not applicable, the Standard for 

Manufactured Home Installation, ANSI A225.1/NFPA 501A. 

   

This appliance, when installed, must be electrically grounded 

in accordance with local codes, or in the absence of local 

codes, with the National Electrical Code, ANSI/NFPA 70-

1987 and CSA C22.2 Canadian Electrical Code for Canada. 

 

  The installation must conform to local codes, or in the 

absence of local codes, with the National Fuel Gas Code ANSI 

Z223.1-1992 (CAN B149. IN CANADA) 

  This appliance complies with ANSI Z21.44-1995, and CAN1 

2.19-M81, IR #41 and #55 as a gravity direct vent wall 

furnace.  
 
 
 
 
 
 
 

MINIMUM INSIDE FIREPLACE DIMENSIONS 
 

The minimum inside dimensions of a masonry or listed factory 
built fireplace are as follows: 
 

• 

Front Width     …………………………            36” 

• 

Back Width      …………………………          17 ¾ “ 

• 

Depth               …………………………          16 ¾ “ 

• 

Height              …………………………            21” 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MINIMUM CHIMNEY SIZE 

 
If the insert is installed in a masonry fireplace, the dimensions 
of the chimney must be a minimum of 7 1/8 “ x 4”. 
 

FOR YOUR SAFETY 

• 

Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other
appliance. 

• 

Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies. 

• 

Do not place clothing or other flammable materials on
or near the appliance. 

• 

NEVER leave children unattended when a fire is
burning in the fireplace. 

WARNING: Improper installation, adjustment,

alteration, service or maintenance can cause injury,
property damage, or loss of life.  Refer to this manual for
assistance or additional information.  Consult a qualified
installer or local distributor. 

CHECK LOCAL CODES BEFORE
INSTALLING THIS FIREPLACE. 

FOR YOUR SAFETY 

WHAT TO DO IF YOU SMELL GAS 

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch. 

• 

Do not use any phone in your building. 

• 

Immediately call your gas supplier from a neighbor’s
phone.  Follow the gas supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the fire
department. 

THIS APPLIANCE MAY BE USED AS A PRIMARY
SOURCE OF HEAT. 

 

INSIDE DIMENSION 

Содержание GW30B

Страница 1: ...valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or accessory items when needed Keep...

Страница 2: ...WITCH PG 4 5 GAS SUPPLY TESTING HOOK UP PG 5 6 SURROUND ASSEMBLY PG 6 8 PILOT ADJUSTMENT PG 7 9 GLASS PANEL REMOVAL PG 7 8 11 LOG INSTALLATION PG 8 12 BURNER FLAME ADJUSTMENT PG 8 13 TERMINATION CAP P...

Страница 3: ...in the absence of local codes with the National Electrical Code ANSI NFPA 70 1987 and CSA C22 2 Canadian Electrical Code for Canada The installation must conform to local codes or in the absence of lo...

Страница 4: ...high traffic areas or near furniture and draperies 2 Never obstruct the front opening of the appliance or the flow of combustion and ventilation air Keep control compartments accessible 3 Do not loca...

Страница 5: ...ated at the upper right corner of the surround as shown in the figure below Wires and toggle switches are supplied with the appliance 3 The wires must be routed through the lower right side of the ins...

Страница 6: ...owever consider installing an extra shut off valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a wall In conformance with loc...

Страница 7: ...hanging through the chimney attach each flex to the appropriate pipe of the insert The pre marked flex pipe is attached over the left pipe Exhaust Tighten the clamp over the flex pipe Repeat the proce...

Страница 8: ...stance of 3 8 to 1 2 from the pilot flame as shown below GLASS PANEL REMOVAL AND LOG SET INSTALLATION Before proceeding make sure gas control valve is in the OFF position 1 To open the louver assembly...

Страница 9: ...r switch is not fully depressed Replace the louver assembly in the reverse order of step 1 BURNER REMOVAL BEFORE PROCEEDING MAKE SURE THE ENTIRE UNIT IS COOL Remove the louver assembly Open the four l...

Страница 10: ...MASONRY CHIMNEY Attach the masonry adapter to the chimney Make sure the flex pipes are protruding out of the chimney for easy connection to the transition box Attach the flex pipes to the transition b...

Страница 11: ...ar appliance may be found on the rating plate located inside the appliance Refer to the parts list and diagrams when ordering replacement parts for your appliance Repair parts or accessory items may b...

Страница 12: ...11 For more information visit www desatech com...

Страница 13: ...res defective Pilot flame maybe too low or blowing high causing the valve safety to drop out Check to see if you have gas supply Hold regulator control valve in the PILOT position for 2 or 3 minutes t...

Страница 14: ...13 For more information visit www desatech com ACCESSORY PARTS LIST...

Страница 15: ...following qualifications 1 The gas appliance must be installed as per the DESA installation instructions and local building codes The use of components manufactured by others with this DESA gas appli...

Отзывы: