background image

www.desatech.com

114926-01B

19

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions 

listed under 

Replacement Parts 

on page 12 of this manual.

KEY 

PART NUMBER

NO.  VTDMV24NA  VTDMV24PA  VTDMV18NA  VTDMV18PA  DESCRIPTION 

QTY.

111793-01 

111793-01 

111808-02 

111808-02 

Grate 

1

111817-02 

111817-02 

111817-02 

111817-02 

Flexible Tube 

1

099998-01 

099998-01 

099998-01 

099998-01 

Fan Switch 

1

103784-02 

103784-02 

103784-02 

103784-02 

Knob Extension (HI/LOW) 

1

103784-01 

103784-01 

103784-01 

103784-01 

Knob Extension (ON/OFF)  1

097159-04 

097159-04 

097159-04 

097159-04 

Piezo Ignitor 

1

114942-01 

114942-01 

114942-01 

114942-01 

Heat Shield 

1

111796-01 

111796-01 

111796-01 

111796-01 

Valve Bracket 

1

111807-01 

111807-02 

111807-01 

111807-02 

Valve 

1

10 

112376-01 

103778-01 

112376-01 

103778-01 

Pilot Assembly 

1

11 

111828-01 

111818-01 

111828-01 

111828-01 

Brass Fitting 

2

12 

114930-01 

114930-01 

114930-01 

114930-01 

Pilot Bracket 

1

13 

26205 

23109 

26205 

23109 

Gas Orifice 

1

14 

114936-01 

114936-01 

114930-01 

114930-01 

Venturi 

1

15 

       ** 

       ** 

       ** 

       ** 

Burner 

1

16 

114933-02 

114933-02 

114933-01 

114933-01 

Plate Burner 

1

17 

       ** 

       ** 

       ** 

       ** 

Log Set 

1

PARTS AVAILABLE NOT SHOWN

 

100563-01 

100563-01 

100563-01 

100563-01 

Warning Plate 

1

 

103877-01 

103877-01 

103877-01 

103877-01 

Lighting Instruction 

1

 

100639-01 

100639-01 

100639-01 

100639-01 

Caution Decal 

1

 

GA6060 

GA6060 

GA6060 

GA6060 

Lave Rock 

1

 

111228-02 

111228-02 

111228-02 

111228-02 

1/8" Flex Gas Line 

1

 

114928-11 

114928-12 

114928-09 

114928-10 

Rating Plate 

1

 

115597-01 

115597-01 

115597-01 

115597-01 

Log Repair Kit 

1

 

112799-01 

112799-01 

112799-01 

112799-01 

Ember Flakes Kit 

2

 

901242-01 

901242-01 

901242-01 

901242-01 

Damper Clamp 

1

Содержание Firewerks VTDMV18NA

Страница 1: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s...

Страница 2: ...33 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This app...

Страница 3: ...ent even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not place log s...

Страница 4: ...ss provided by other means screens shall have openings for introduction of combustion air 8 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 SAFETY INFORMATION Cont...

Страница 5: ...d ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must be cleaned of soot creo sote ashes and loose paint...

Страница 6: ...nly in a solid fuel burning or UL127 factory built re place constructed of noncombustible material and connected to a working ue The replace chimney must have a permanent vent opening to outside with...

Страница 7: ...ction to the control valve INSTALLATION Continued CAUTION Never connect propane LP unit directly to the propane LP supply This unit re quiresanexternalregulator not supplied Install the external regul...

Страница 8: ...ssure Propane LP From External Regulator 11 W C to 14 W C Pressure 3 Min Pipe Cap Tee Nipple Joint CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections for leaks after installing or servi...

Страница 9: ...valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from equipment shutoff valve to gas control see Figure 9 or 10 Apply noncorrosive leak detection uid to all joint...

Страница 10: ...d separately see Accessories page 17 Follow instructions included with the remote control OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep ue open when operating unit WARNING If y...

Страница 11: ...e thermocouple to cool When the thermocouple cools the appliance will shut down If pilot ame pattern is incorrect as shown in Figure 16 turn appliance off see To Turn Off Gas to Appliance page 10 see...

Страница 12: ...ignition propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questions about i...

Страница 13: ...in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is in correct When ignitor button is pressed there is no spark at ODS pilot When igni...

Страница 14: ...page 17 1 Contact local natural or propane LP gas company 2 Clean burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner ori ce 2 Replace d...

Страница 15: ...2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and...

Страница 16: ...nding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP onl...

Страница 17: ...2 6040 for referral information You can also write to the address listed on the back page of this manual EQUIPMENT SHUTOFF VALVE GA5010 Equipment shutoff valve with 1 8 NPT tap Fits 1 2 pipe FIREPLACE...

Страница 18: ...www desatech com 114926 01B 18 ILLUSTRATED PARTS BREAKDOWN VTDMV24NA VTDMV24PA VTDMV18NA VTDMV18PA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Страница 19: ...ket 1 9 111807 01 111807 02 111807 01 111807 02 Valve 1 10 112376 01 103778 01 112376 01 103778 01 Pilot Assembly 1 11 111828 01 111818 01 111828 01 111828 01 Brass Fitting 2 12 114930 01 114930 01 11...

Страница 20: ...The heater MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditi...