background image

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com

NOT A UPC

Model

Serial No.

Date Purchased

114926-01
Rev. B
01/05

114926 01

WARRANTY INFORMATION

KEEP THIS WARRANTY

Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our 

standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY 

VENTED GAS LOG APPLIANCES

DESA warrants this product to be free from defects in materials and components for four (4) years from the date 

of first purchase, provided that the product has been properly installed, operated and maintained in accordance 

with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be 

presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to 

restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized 

Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who 

will provide original factory replacement parts. Failure to use original factory replacement parts voids this war-

ranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions 

furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that 

fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper 

installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a 

defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE 

OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED 

WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) 

YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESAʼS LIABILITY IS 

HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE 

FOR ANY  OTHER  DAMAGES WHATSOEVER  INCLUDING  INDIRECT,  INCIDENTAL  OR  CONSE-

QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of 

incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on 

damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:

Содержание Firewerks VTDMV18NA

Страница 1: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s...

Страница 2: ...33 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This app...

Страница 3: ...ent even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not place log s...

Страница 4: ...ss provided by other means screens shall have openings for introduction of combustion air 8 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 SAFETY INFORMATION Cont...

Страница 5: ...d ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must be cleaned of soot creo sote ashes and loose paint...

Страница 6: ...nly in a solid fuel burning or UL127 factory built re place constructed of noncombustible material and connected to a working ue The replace chimney must have a permanent vent opening to outside with...

Страница 7: ...ction to the control valve INSTALLATION Continued CAUTION Never connect propane LP unit directly to the propane LP supply This unit re quiresanexternalregulator not supplied Install the external regul...

Страница 8: ...ssure Propane LP From External Regulator 11 W C to 14 W C Pressure 3 Min Pipe Cap Tee Nipple Joint CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections for leaks after installing or servi...

Страница 9: ...valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from equipment shutoff valve to gas control see Figure 9 or 10 Apply noncorrosive leak detection uid to all joint...

Страница 10: ...d separately see Accessories page 17 Follow instructions included with the remote control OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep ue open when operating unit WARNING If y...

Страница 11: ...e thermocouple to cool When the thermocouple cools the appliance will shut down If pilot ame pattern is incorrect as shown in Figure 16 turn appliance off see To Turn Off Gas to Appliance page 10 see...

Страница 12: ...ignition propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questions about i...

Страница 13: ...in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is in correct When ignitor button is pressed there is no spark at ODS pilot When igni...

Страница 14: ...page 17 1 Contact local natural or propane LP gas company 2 Clean burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner ori ce 2 Replace d...

Страница 15: ...2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and...

Страница 16: ...nding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP onl...

Страница 17: ...2 6040 for referral information You can also write to the address listed on the back page of this manual EQUIPMENT SHUTOFF VALVE GA5010 Equipment shutoff valve with 1 8 NPT tap Fits 1 2 pipe FIREPLACE...

Страница 18: ...www desatech com 114926 01B 18 ILLUSTRATED PARTS BREAKDOWN VTDMV24NA VTDMV24PA VTDMV18NA VTDMV18PA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Страница 19: ...ket 1 9 111807 01 111807 02 111807 01 111807 02 Valve 1 10 112376 01 103778 01 112376 01 103778 01 Pilot Assembly 1 11 111828 01 111818 01 111828 01 111828 01 Brass Fitting 2 12 114930 01 114930 01 11...

Страница 20: ...The heater MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditi...