background image

7

107434

OWNER’S MANUAL

For more information, visit www.desatech.com

 WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

INSTALLATION

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural gas, do not install heater. Call
dealer where you bought heater for proper
type heater.

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

CLEARANCES TO
COMBUSTIBLES

(Vent-Free Operation Only)

  WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining side
and back walls.

Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor. 

IMPORTANT:

 You

must maintain minimum wall and ceiling
clearances during installation. The mini-
mum clearances are shown in Figure 4.
Measure from outermost point of stove top.

Minimum Wall and Ceiling
Clearances (see Figure 4)

A. Clearances from outermost point of

stove top to any combustible side wall
should not be less than 12 inches.

B. Clearances from outermost point of

stove top to any combustible back wall
should not be less than 6 inches (In-
cludes corner installations).

C. Clearances from the stove top to the

ceiling should not be less than 48
inches.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Figure 4 - Minimum Clearance to Walls and Ceiling

Front View

Continued

12"

Minimum

12"

Minimum

48"

Minimum

Ceiling

Side Wall

Side Wall

Top View

Side View

Front of

Stove Unit

Back Wall

Side Wall

Side Wall

12 

"

Minimum

12 

"

Minimum

"

Minimum

6"

Minimum

48"

Minimum

Ceiling

Floor

Back Wall

Corner

Wall

Wall

"

Minimum

"

Minimum

Содержание Comfort Glow S39NT

Страница 1: ...If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adj...

Страница 2: ...urn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 8 This heater needs fresh outside air ven tilation to run...

Страница 3: ...UNPACKING 1 Remove top inner pack 2 Tilt carton so that stove is upright 3 Remove protective side packaging 4 Slide stove out of carton 5 Remove protective plastic wrap 6 Remove screen by lifting and...

Страница 4: ...eater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure proper fre...

Страница 5: ...rect vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the...

Страница 6: ...tilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within...

Страница 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Страница 8: ...r cleaning Install in piping system betweenfuelsupplyandheater Locatesedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from go...

Страница 9: ...nnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 7 2 Press...

Страница 10: ...ols required Phillips screwdriver NOTICE Shutoffgasheaterduring the following blower installation 1 Remove 2 screws from rear tabs on top trim Pull trim forward to remove see Figure 11 2 Remove top pa...

Страница 11: ...inside control compartment door in front of stove see Figure 16 15 Using two screws provided in blower kit mount blower speed control hous ing to mounting tab in left side of lower control compartment...

Страница 12: ...after servicing Wiring Diagram Decal Figure 18 Attaching Wire Harness to ThermostaticSwitchandCoverAssembly Thermostatic Switch Mounted to Cover Wire Harness Lower Hole Figure 19 Assembling Thermosta...

Страница 13: ...ighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier th...

Страница 14: ...n and burner flame patterns often PILOT FLAME PATTERN Figure 23 shows a correct pilot flame pat tern Figure 24 shows an incorrect pilot flame pattern Note Appearance of pilot assembly may vary by mode...

Страница 15: ...cleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can...

Страница 16: ...ged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set...

Страница 17: ...ute 2 Operate burner until air is removed from line Have gas line checked by local natu ral gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning and...

Страница 18: ...ater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or to...

Страница 19: ...ent Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462...

Страница 20: ...20 107434 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39NT 7 6 9 4 10 3 2 1 14 5 12 11 10 8 13...

Страница 21: ...manual KEY PART NO NUMBER DESCRIPTION QTY 1 107433 02 Log Set 1 2 104285 01 ODS Pilot NG 1 3 098249 01 ODS Nut 2 4 107090 01 Burner Outlet Tube 1 5 107089 01 Inlet Tube 1 6 102843 01 Burner Clip 1 7...

Страница 22: ...107434 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39NT 1 10 4 13 3 2 14 7 16 15 11 18 20 5 6 9 8 17 12 23 21 19 19 26 26 22 22 21 25...

Страница 23: ...9 107080 01CK Firebox Floor 1 10 107081 01CJ Firebox Top 1 11 107365 01CK Screen Assembly 1 12 101382 01 Valve Bracket 1 13 107092 01 Brass Trim Bottom 1 14 107093 01 Brass Trim Firebox 1 15 105576 0...

Страница 24: ...nt part s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready model number of your heater the replacement part number ACCESSORI...

Страница 25: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Страница 26: ...sedbyimproperinstallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTEN...

Отзывы: