INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the mini-
mum clearances. If you can, pro
-
vide greater clearances from floor,
ceiling and adjoining wall.
INSTALLATION
Continued
LOG SIZING REQUIREMENTS
Minimum Firebox
Height
Depth
Front
Rear *
Width
Width
17"
14"
8"
1"
* Measured at 14" depth.
MINIMUM FIREPLACE CLEARANCE TO
COMBUSTIBLE MATERIALS
Side Wall
Ceili
ng
16"
4"
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-listed
manufactured fireplace or listed vent-free firebox.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This combus-
tible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note:
When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace opening
to the ceiling should not be less than 42".
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
Example
NOTICE: Manual control heaters
may be used as a vented product.
If so, you must always run heater
with chimney flue damper open.
If running heater with damper
open, noncombustible material
above fireplace opening is not
needed. Go to
Installing Damper
Clamp Accessory for Vented
Operation
, page 11.
MINIMUM NONCOMBUSTIBLE
MATERIAL CLEARANCES
If Not Using Mantel
Note:
If using a mantel proceed to
If Using Mantel.
If not using a mantel, follow the information on
this page.
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have non
-
combustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
must install the fireplace hood accessory. See Figure
5, page 10, for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have non
-
combustible material behind it. Noncombustible
material must extend at least 8" up). If noncombus
-
tible material is less than 12", you must install the
fireplace hood accessory. Even if noncombustible
material is more than 12", you may need the hood
accessory to deflect heat away from your mantel
shelf. See Figures 5, 6 and 7, page 10, for minimum
clearances.
IMPORTANT:
If you cannot meet these minimum
clearances, you must operate heater with chimney
flue damper open. Go to
Installing Damper Clamp
Accessory for Vented Operation
, page 11.
*