www.desatech.com
123721-01E
9
Figure 4 - Assembling Hood
Hood
Sheet Metal
Screws
Firebox Top
Louver
iNsTallaTioN
Continued
Note: When installing fireplace directly on
carpeting, tile or other combustible material,
other than wood flooring, the fireplace shall be
installed on a metal or wood panel extending
the full width and depth of the fireplace.
Use the dimensions shown for rough openings
to create the easiest installation (see
Built-In
Fireplace Installation
, page 11).
CHECK GAS TyPE
Use only the correct gas type (natural or
propane/LP) for your unit. If you do not know
your gas type, do not install heater. The heater
leaves the factory set for propane/LP gas. If
natural gas is desired, a qualified installer can
perform the simple conversion to natural gas
by following the instructions on page 13.
WARNING: This appliance
is equipped for natural and
propane/LP. Gas type is indi
-
cated on the rating plate. Field
conversion is not permitted
other than between natural or
propane gases.
INSTALLATION ITEMS
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer, for
propane/LP units only)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection*
• ground joint union
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al
-
ternative to test gauge connection. Purchase
the optional CSA design-certified equipment
shutoff valve from your dealer.
Note: If desired, purchase a four-sided pe-
rimeter trim kit for built-in installations. See
Accessories, page 33.
HOOD ASSEMBLy
WARNING: Always have
hood in place before operating
fireplace. This prevents exces
-
sive temperatures on fireplace
surfaces.
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this fireplace may result in prop
-
erty damage or personal injury.
Tools Required:
• Phillips screwdriver • slotted screwdriver
• 5/16" hex wrench
• scissors
1. Remove log from firebox. Set log aside.
2. An optional blower is available. See
Ac-
cessories,
page 33. Install optional blower
now. Follow installation instructions pro
-
vided with blower.
3. Locate 4 black Phillips sheet metal screws
in hardware packet.
4. Slide hood between louver and firebox top
and align screw holes.
5. Insert screws as shown in Figure 4.
Tighten screws firmly.